Troubleshooting, 1 fatal fault error codes) – Rapid-Air MINI-SERVO FEED: MS2, MS4 & MS8. 115vac, 1ph, 60hz User Manual

Page 8

Advertising
background image



1

2

3

4.0

4.1

4.2

4.3

4.4

4.5

4.6

4.7

4.8

4.9

5

6

7.1

7.2

8

8.1

9

10

12

14.1

14.2

15.1

15.2

16

TroUbleshooTinG

(7.3.1 fATAl fAUlT error Codes)

Error.#...Status.Display...........Fault.Message....................................Possible.Cause

t

o

p

r0

r1

r2

r3

r4

r5

r6

r7

r8

r9

u

II

A1

A2

J

J1

E

e

F

d5

d6

d1

d2

c

Power stage OverTemp

OverVoltage

OverCurrent

External feedback fault

Resolver line break

RDC error

Sinc Encoder init fail

A/B line break

Index line break

Illegal halls

C/D line break

A/B out of range

Burst pulse overflow

Under voltage

Motor over temperature

Positive analog supply fail

Negative analog supply fail

OverSpeed

OverSpeed

EEPROM failure

EEPROM checksum fail

Foldback

Positive over travel fault

Negative over travel fault

Numeric position deviation

Excessive position deviation

Communication interface

overload, fan malfunction, power stage failure

excessive decel rate*

power stage surge current*

feedback signal through C8 not correctly detected

break in resolver feedback detected

fault in resolver-to-digital converted detected

sinc encoder card has not initialized properly

break in encoder A/B input lines detected

break in encoder index line

illegal hall combination detected

break in sinc encoder C/D line detected

sinc encoder A/B level out of range

sinc encoder fault

bus voltage is too low

motor overload caused overheating

failure in +12V supply

failure in -12V supply

velocity ≥ VOSPD

velocity ≥ 1.8 x VLIM

faulty EEPROM

EEPROM checksum invalid on power up*

system in foldback mode

PFB exceeded PMAX with PLIM=1

PFB exceeded PMIN with PLIM=1

internal fault

PE > PEMAX

a communications fault has occurred

* These faults can only be cleared by cycling power.