RESET JOB PARAMETERS

The reset job parameters routing should be used with special caution. We
incorporated it as a user function for two reasons.

The first reason is if a problem caused the displayed parameters to be garbled because
of a program glitch, then by resetting the job parameters the problem could be cleared.

The second reason is if there were a number of different jobs in memory that were no
longer required, then by resetting the job parameters, all the job numbers would be reset
to their default values, which includes putting all zeros in the feed length and strokes per
minute area of the program.


CAUTION!! CAUTION!! CAUTION!!
Keep a hard copy record of program numbers and data associated with them for
reference if needed. If this function is used in a way other than what it was designed for
then all previous data is lost and cannot be recovered.

To enter this function, turn off the program by depressing the master stop button. Turn on
the program again and push and hold the “clear entry” key, once the program has started
the following screen will be displayed.

**DEFAULT VALUE SETUP
PRESS F1 TO RESET TO
DEFAULT VALUES, PRESS
F4 TO IGNORE CHANGES

**Once F1 has been pressed then all data that had been entered will be reset.


PROGRAM NUMBER DISPLAY

Each servo unit that is shipped has a program number assigned to it. If a problem occurs
and cannot be solved by reloading the program then you will be asked the program
number associated with this servo.

To view the program number, press and hold the “back space” key during the power up
sequence. The program number will be displayed for about 30 seconds. Please find and
write down the program number in case it is needed in the future.