Rapid-Air SERVO FEED GAG FEED: 950 SERIES User Manual

Page 24

Advertising
background image

23

Pressing the F4 key, stops the automatic cycle and the main menu screen appears. When
the automatic screen is displayed, all keys except the F4 key are inactive. Every time the
press cycles and trips the feed switch, the feed will cycle once per the parameters
displayed on the screen. If the feed encounters excessive materail drag while feeding or
the material being moved encounters a restriction taht stops the material forward
movement then a servo fault can occur. If this happens then the following screen is
displayed.

DRIVE FAULT OCCURED
NOTE TYPE OF FAULT—-
(xxx
*example of fault
2 - motor over temperature

If this screen is displayed then the control cabinet has to be opened and the Pac-Sci drive
has to be checked. To reset the fault, the master on-off switch has to be cycled which will
reset the controller. The material path should be checked for obstruction and parrallelism
to the die. If all this seems to be satisfactory and another fault occurs the factory should be
consulted.

MAIN MENU
F1=JOB # F2=MANUAL
F3=AUTOMATIC CYCLE
F4=REVIEW JOB PROGRAM
F4=JOB REVIEW

Pressing the F4 key will display the following screen. This screen asks for a sequence
number to be reviewed or modified. The program only allows reviewing of a sequence in
the job that is currently active. For an example, if job #1 had 4 sequences and sequnce 1
was not functioning correctly then put ina 01 at this time.

REVIEW OR MODIFY SEQ
JOB NUMB=00 ENTER IN
THE SEQ=00 THEN
PRESS F4 TO CONTINUE

Pressing the F4 key will display the following screen.

JOB#=00 SEQUENCE#=00
FL=000.000 REPEAT=00
OUT=00000000 PILOTS=0
SPEED=000 ACCEL=000

The above screen displays the job number and the sequence that was selected. If all that
was needed was to look at the sequence to verify that it was correct then pressing the F4
key will return you to the main menu. If there was a problem with this particular

Advertising