Installation

‚ 37

3.

Attach the C2000 pump connection cable to the connector
on the Tokheim configurator box. Be sure to screwlock
this connector to the Tokheim configurator box with the
screws provided.

4.

For systems with eight pumps or less, connect the C2000
pump connection cable directly to the Model 98
Computer/Power Center. For systems with more than eight
pumps (two Model 98 Computer/Power centers) use a "Y"
cable (optional component, available through Progressive
International Electronics) between the Tokheim
configurator box and the Model 98 Computer/Power
Centers. Ensure that cables are screwlocked together.
The connection must not be subjected to harsh
environments such as under water, extreme heat or
extreme cold, etc.

5.

Connect the wall transformer into a 115 VAC receptacle.