Setting the variable text code – AMX Wireless Touch Panels (Wave Server) User Manual

Page 40

Advertising
background image

30

Designing Touch Panel Pages

ViewPoint Wireless Touch Panels

b. For 2-way ViewPoints, AMX IR is not supported (38 KHz and 455 KHz) but

other manufacturer’s IR codes are supported by assigning ViewPoint device
numbers 2, 3, and 4 for IR codes.

3.

Press ENTER to store the device number into memory, close the keypad, and
return to the Button Properties page.

4.

Press CHAN to open a keypad and enter a channel value of 1 through 255 in the
keypad. The AXCESS software program uses the channel code number to
identify the button and its’ programmed operations.

5.

Enter 1 through 255 in the keypad. The AXCESS software program uses the
channel code number to identify the button and its operations.

6.

Press ENTER to store the channel number in memory, close the keypad, and
return to the Button Properties page.

Setting the variable text code

The variable text buttons that set the device and button channel codes for the touch
panels are shown in Figure 37.

1.

Press DEV to open a keypad and set the device number.

2.

Enter 1, 2, 3, or 4 in the keypad. The AXCESS software program uses device
codes 1 through 4 to identify the touch panel. Refer to the Touch Panel Program
Reference
section in this manual for detailed information.

3.

Press ENTER to store the device number in memory, close the keypad, and
return to the Button Properties page.

4.

Press CHAN to open a keypad and set the channel number.

5.

Enter a channel value of 1 through 255 in the keypad. The AXCESS software
program uses the channel code number to identify the button and its operations.

6.

Press ENTER to store the channel number into memory, close the keypad, and
return to the Button Properties page.

Note

If DEVICE USED is set to 4

and Base Device Number is

128, the Central Controller

recognizes bus devices 128,

129, 130, and 131.

Note

The channel code for non-

active buttons is 0 and for

active buttons is 1 through

255.

Note

One-way ViewPoint touch

panels do not support variable

text.

Figure 37

VAR TEXT code button

Note

The panel will not allow you to

enter a device number greater

than the DEVICE USED

without first displaying a

decision box. This box asks

you to decide whether you

accept the new selection or

default to the previous value.

Note

The channel codes for non-

active buttons is 0, and active

buttons is 1 through 255.

Advertising