(2) Attach the first EX module to the rear

side of the LT.
Insert the extension connector at the
left side of the first EX module to the
EX module interface (EXT1)of the LT.
Attach the second and third EX
modules in a similar manner.

(3) Push down the latch buttons on the top

to secure the EX module to the LT.

• Make sure to fix the EX modules to the

LT securely using the latch buttons.

• Up to two EX modules can be connected

to the rear side of the LT-3200 Series.

• Up to three EX modules can be

connected to the rear side of the LT-
3300 Series. Only the third EX module

must be fixed with the securing hook
attached to the LT

• As for EXM-DMM24DRF and EXM-

ARI8LT, only one EX module can be
connected to an LT.

*1 Before the insertion step, determine the position

of the rectangular hole. The appropriate
position varies depending on the combination
of the EX modules that you use.

„

Removal

(1) To remove the EX module, push up the

latch buttons to unlock it.

The Second
EX Module

The First
EX module

Peel the label
off before
attaching the
second EX
module.

EX Module I/F
(EXT1)

Push down the latch
button.

Pushed out and
then secured.

(2) Insert the projection

of the securing
hook into the
securing hole.

(1) Insert the end of the securing

hook into the rectangular
hole appropriately.*1

EX module attachment
completion drawing

Latch buttons released when pushed out

Press latch buttons
upward.

(LT-3200 Series)