Operation – Alliance Laundry Systems UF18PNV User Manual

Page 17

Advertising
background image

Operation

16

F232072

Display Indications

Display

Meaning

Display

Meaning

FP1

Program identification code (ROM). This is an
example only.

Med

Medium water level

Hold

Wait...power has just been turned on.

HI

High water level

CY

Cycle (followed by two-digit number)

SUP1

Supply 1

tESt/CYC*

Test cycle selected.

SUP2

Supply 2

FAr

Degrees Fahrenheit

SUP3

Supply 3

CEL

Degrees Celsius

SUP4

Supply 4

Heat

Auxiliary heat enabled.

SUP5

Supply 5 (SETUP option)

noHt

Auxiliary heat disabled.

SUP6

Supply 6 (supply 1 and 5)

tFIL

Temperature-controlled fill enabled.

SUP7

Supply 7 (supply 3 and 4)

ntFL

Temperature-controlled fill disabled.

SLo/For

Gentle wash speed, forward direction

CooL

Automatic cool-down enabled.

SLo/rEv

Gentle wash speed, reverse direction

noCL

Automatic cool-down disabled.

norM/For

Normal wash speed, forward direction

Ag 1

Agitation 1 selected (90% agitation).

norM/rEv

Normal wash speed, reverse direction

Ag 2

Agitation 2 selected (33% agitation).

drAI

Drain enabled.

Ag 3

Agitation 3 selected (10% agitation).

nodr

Drain disabled.

Ag 4

Agitation 4 selected (6.7% agitation).

dISt

Distribution (load balancing before extract)

AgSn

Agitation speed normal

SPIn/tIME*

Reads “SPIn” for one second, then “tIME”
followed by time for spin.

AgSL

Agitation speed low

PMP

Pump output enabled (future use only).

SPn1

Lowest of three spins

nPMP

Pump output disabled (future use only).

SPn2

Middle of three spins

PrE

Prewash segment (1st of 11 segments)

SPn3

Highest of three spins

UASH

Wash segment (2nd of 11 segments)

STOP

Stop routine

FIL1

First fill (3rd of 11 segments)

SdLY

Spin coast delay

FIL2

Second fill (4th of 11 segments)

donE

Cycle and stop routine have ended.

FIL3

Third fill (5th of 11 segments)

dFLt

Drive fault detected.

FIL4

Fourth fill (6th of 11 segments)

door

Door not properly closed.

FIL5

Fifth fill (7th of 11 segments)

bAL/FAIL*

Balancing routine failed during test cycle after
10 attempts to balance load.

FIL6

Sixth fill (8th of 11 segments)

FIL7

Seventh fill (9th of 11 segments)

FILL/STOP*

Programmed water level not reached after 30
minutes.

FIL8

Eighth fill (10th of 11 segments)

FIL9

Ninth fill (11 of 11 segments)

FULL

The computer detects low water level or higher
when none should be present.

CFIL

Cold fill

bFIL

Warm fill (both hot and cold)

rotA

Computer detects possible rotation of motor
when there should be none.

HFIL

Hot fill

AFIL

Auxiliary fill (SETUP option)

tSFL

Temperature sensor failure or temperature out of
range.

Lo

Low water level

*Display indications separated by a slash represent a flashing display.

Advertising