Programming – Alliance Laundry Systems UF18PNV User Manual

Page 28

Advertising
background image

F232072

27

Programming

1. Press the Up key until the computer display

shows the segment to be edited. Press the Start
key.

2. Use the Up or Down key to select the desired

segment time. Set this value to zero to skip the
segment. Press the Start key.

Note:

The computer does not count down the

remaining cycle time during fills, drains, cool-
down, or prior to first achieving the programmed
heat temperature when heating. The computer
resumes counting down cycle time once the
programmed fill level is reached, when the machine
has drained, and after a programmed heat
temperature is reached.

3. If the temperature-controlled fill SETUP option

is enabled, the display will show “tFIL.” Press
the Start key.

4. Use the Up or Down key to select the desired

fill temperature. See the following table for fill
options.

If the temperature-controlled fill SETUP option
is enabled and a target temperature is set, the
selected fill valve(s) will energize for the first 3
seconds of the segment fill. The computer will
then begin operating the fill valves in an attempt
to reach the target temperature. Press the Start
key.

Note:

If “AFIL” is selected and the temperature-

controlled fill SETUP option is set to “tFIL,” the
temperature for the segment must be set to zero.

5. Use the Up or Down key to select the desired

fill level. See the table below.

6. Press the Start key.

Fill Temperature Options

Display

Fill Type

CFIL

Cold fill

HFIL

Hot fill

bFIL

Warm fill

AFIL

Auxiliary fill*

*This is available only if the “SUP5”/“AFIL” SETUP

option is set to “AFIL.”

Water Level Options

Display

Fill Level

LO

Low Level

Med

Medium Level

HI

High Level

Advertising