2 csa certification, Csa certification -6 – Yokogawa EJA310E User Manual

Page 14

Advertising
background image

<2. Handling Cautions>

2-6

IM 01C25B01-01E

2.9.2 CSA Certification

a. CSA Intrinsically Safe Type

Caution for CSA Intrinsically safe and

nonincendive type. (Following contents refer to

“DOC No. ICS013-A13”)

Note 1. Model EJX/EJA-E Series differential,

gauge, and absolute pressure transmitters

with optional code /CS1 are applicable for

use in hazardous locations

Certificate: 1606623

[For CSA C22.2]

• Applicable Standard: C22.2 No.0, C22.2

No.0.4, C22.2 No.25, C22.2 No.94, C22.2

No.157, C22.2 No.213, C22.2 No.61010-1,

C22.2 No.60079-0

• Intrinsically Safe for Class I, Division 1,

Groups A, B, C & D, Class II, Division 1,

Groups E, F & G, Class III, Division 1

• Nonincendive for Class I, Division 2, Groups

A, B, C & D, Class II, Division 2, Groups E, F

& G, Class III, Division 1

• Enclosure: NEMA TYPE 4X

• Temp. Code: T4

• Amb. Temp.:–50* to 60°C

* –15°C when /HE is specified.

• Process Temperature: 120°C max.

[For CSA E60079]

• Applicable Standard: CAN/CSA E60079-11,

CAN/CSA E60079-15, IEC 60529:2001

• Ex ia IIC T4, Ex nL IIC T4

• Ambient Temperature: –50* to 60°C

* –15°C when /HE is specified.

• Max. Process Temp.: 120°C

• Enclosure: IP66/IP67

Note 2. Entity Parameters

• Intrinsically safe ratings are as follows:

Maximum Input Voltage (Vmax/Ui) = 30 V

Maximum Input Current (Imax/Ii) = 200 mA

Maximum Input Power (Pmax/Pi) = 0.9 W

Maximum Internal Capacitance (Ci) = 10 nF

Maximum Internal Inductance (Li) = 0 µH

• Type "n" or Nonincendive ratings are as

follows:

Maximum Input Voltage (Vmax/Ui) = 30 V

Maximum Internal Capacitance (Ci) = 10 nF

Maximum Internal Inductance (Li) = 0 µH

• Installation Requirements

Uo ≤ Ui, Io ≤ Ii, Po ≤ Pi,

Co ≥ Ci + Ccable, Lo ≥ Li + Lcable

Voc ≤ Vmax, Isc ≤ Imax,

Ca ≥ Ci + Ccable, La ≥ Li + Lcable

Uo, Io, Po, Co, Lo, Voc, Isc, Ca and La are

parameters of barrier.

Note 3. Installation

• In any safety barreir used output current

must be limited by a resistor 'R' such that

Io=Uo/R or Isc=Voc/R.

• The safety barrier must be CSA certified.

• Input voltage of the safety barrier must be

less than 250 Vrms/Vdc.

• Installation should be in accordance with

Canadian Electrical Code Part I and Local

Electrical Code.

• Dust-tight conduit seal must be used when

installed in Class II and III environments.

• The instrument modification or parts

replacement by other than authorized

representative of Yokogawa Electric

Corporation and Yokogawa Corporation

of America is prohibited and will void

Canadian Standards Intrinsically safe and

nonincendive Certification.

F0204-1.ai

Class I, II, III, Division 1,

Groups A, B, C, D, E, F, G
Pressure Transmitters

Safety Barrier

Supply

Hazardous Location

Nonhazardous Location

General

Purpose

Equipment

+

+

+

+

[Intrinsically Safe]

Group IIC, Zone 0

F0204-2.ai

Pressure Transmitters

Supply

Hazardous Location

Nonhazardous Location

+

+

Class I, II, Division 2,

Groups A, B, C, D, F, G

Class III, Division 1.

Not Use

Safety Barrier

[Nonincendive]

CSA Certified

Equipment

([nL] or

nonincendive)

Group IIC, Zone 2

b. CSA Explosionproof Type

Caution for CSA explosionproof type.

Note 1. Model EJX/EJA-E Series pressure

transmitters with optional code /CF1 are

applicable for use in hazardous locations:

• Certificate: 2014354

• Applicable Standard: C22.2 No.0,

C22.2 No.0.4, C22.2 No.0.5, C22.2 No.25,

C22.2 No.30, C22.2 No.94,

C22.2 No.61010-1, C22.2 No.60079-0,

C22.2 No.60079-1

Advertising