Yokogawa EJA115 User Manual

Page 17

Advertising
background image

IM 01C22K01-01E

2-9

2. HANDLING CAUTIONS

• Take care not to generate mechanical sparking

when accessing to the instrument and peripheral
devices in a hazardous location.

Note 5. Maintenance and Repair

• The instrument modification or parts replacement

by other than authorized representative of
Yokogawa Electric Corporation is prohibited and
will void KEMA Flameproof Certification.

c. CENELEC ATEX (KEMA) Intrinsically Safe

Type/CENELEC ATEX (KEMA) Flameproof
Type/CENELEC ATEX Type n

Model EJA Series pressure transmitters with
optional code /KU2 can be selected the type of
protection CENELEC ATEX (KEMA) Intrinsi-
cally Safe, Flameproof or CENELEC ATEX
Type n for use in hazardous locations.

Note 1. For the installation of this transmitter,

once a particular type of protection is
selected, any other type of protection
cannot be used. The installation must be
in accordance with the description about
the type of protection in this user’s
manual.

Note 2. In order to avoid confusion, unnecessary

marking is crossed out on the label other
than the selected type of protection when
the transmitter is installed.

• CENELEC ATEX Type of Protection “n”

WARNING

When using a power supply not having a non-
incendive circuit, please pay attention not to
ignite in the surrounding flammable atmosphere.
In such a case, we recommend using wiring
metal conduit in order to prevent the ignition.

• Applicable Standard: EN60079-15
• Referential Standard: IEC60079-0, IEC60079-11
• Type of Protection and Marking Code:

Ex nL IIC T4

• Temperature Class: T4
• Enclosure: IP67
• Process Temperature: 120

°C max.

• Ambient Temperature: –40 to 60

°C

Note 1. Electrical Data

Ui = 30 V
Effective internal capacitance; Ci = 22.5 nF
Effective internal inductance; Li = 730

µH

Note 2. Installation

• All wiring shall comply with local installation

requirements. (refer to the installation diagram)

Note 3. Maintenance and Repair

• The instrument modification or parts replacement

by other than authorized representative of
Yokogawa Electric Corporation is prohibited and
will void Type of Protection “n”.

Power Supply

(Zone 2 only)

Transmitter

Supply

Nonhazardous Location

[Installation Diagram]

Hazardous Location

+

+

F0209.EPS

Ratings of the Power Supply as follows;

Maximum Voltage: 30 V

• CENELEC ATEX Type of Protection “Dust”

• Applicable Standard: EN50281-1-1:1997
• Type of Protection and Marking Code: II 1D
• Maximum surface temperature: T65

°C (Tamb.:

40

°C), T85°C (Tamb.: 60°C), and T105°C (Tamb.:

80

°C)

Note 1. Installation instructions

The cable entry devices and blanking
elements shall be of a certificated type
providing a level of ingress protection of
at least IP6x, suitable for the conditions
of use and correctly installed.

(2) Electrical Connection

The type of electrical connection is stamped near
the electrical connection port according to the
following marking.

F0200.EPS

Location of the marking

(3) Installation

WARNING

• All wiring shall comply with local installation

requirement and local electrical code.

• There is no need of the conduit seal for both of

Division 1 and Division 2 hazardous locations
because this product is sealed at factory.

• In case of ANSI 1/2 NPT plug, ANSI hexagonal

wrench should be applied to screw in.

Advertising