3 rotating transmitter section, Rotating transmitter section -2 – Yokogawa EJA115 User Manual

Page 23

Advertising
background image

IM 01C22K01-01E

4-2

4. INSTALLATION

Transmitter
mounting bolt

Transmitter
mounting bolt

Mounting bracket

Mounting bracket

50 mm(2-inch) pipe

50 mm(2-inch) pipe

U-bolt

U-bolt

F0402.EPS

Vertical pipe mounting(Manifold upside)

Vertical pipe mounting(Manifold downside)

U-bolt nut

U-bolt nut

Figure 4.2.2 Transmitter Mounting (Vertical Impulse Piping

Type)

4.3 Rotating Transmitter Section

The DPharp transmitter section can be rotated in 90

°

segments.

1) Remove the two Allen screws that fasten the

transmitter section and capsule assembly, using the
Allen wrench.

2) Rotate the transmitter section slowly in 90

° seg-

ments.

3) Tighten the two Allen screws to a torque of 5 N·m.

IMPORTANT

Do not rotate the transmitter section more than
180°.

F0403.EPS

Vertical impulse pipe

Horizontal impulse pipe

Pressure-detector section

Transmitter section

Rotate 90

Њ or 180Њ segments

Rotate 90

Њ or 180Њ segments

Transmitter section

Pressure-detector section

Conduit connection

Conduit connection

Zero-adjustment screw

Figure 4.3

Rotating Transmitter Section