2 specification, 2 specification -3 – Yokogawa BT200 User Manual

Page 10

Advertising
background image

<Toc> <Ind>

<2. INTRODUCTION TO BT200>

2-3

IM 01C00A11-01E

2.2 SPECIFICATION

Equipment Specifications

Applicable Equipment

DPharp Series
ADMAG Series
YEWFLO Series
YTA Series
CENTUM, Signal Conditioner

Communication Signal Connection:

Dedicated cable, 1.1 m long(3.6 ft)

Communication Line:

Line length: Up to 2 km (1.24 mile)(0.75 to 1.25
mm

2

instrumentation cable)

Load resistance: 250 to 600

Ω (including cable

resistance)
Load capacitance: 0.22

µF or less

Load inductance: 3.3 mH or less
Power line spacing: 15 cm (6 inch) or more (avoid
parallel wiring.)

Display: LCD dot matrix, 21 characters

ϫ 8 lines

Controls: Membrane switches (four function keys, 20

general operation keys, and one power switch)

Printer (BT200-P00): Thermal paper type
Power Supply: Five AA 1.5 V dry alkali batteries

(LR6/AM3(N))

Dimensions:

BT200-N00 · · · 228

ϫ110ϫ51 mm

(9.0

ϫ4.3ϫ2.0 inch)

BT200-P00 · · · 321

ϫ110ϫ61 mm

(12.6

ϫ4.3ϫ2.4 inch)

Approximate Weight:

BT200-N00 · · · 510 g (1.12 lb)
BT200-P00 · · · 700 g (1.54 lb)

Functional Specifications

Basic Functions:

• Setup, alteration, and display of parameters

BRAIN communication.

Additional Functions:

• Batch upload/download of data
• Setpoint Protection: Security code enter is required

to alter setpoints.

• Battery Alarm ··· An alarm message appearing on

the LCD signals low battery voltages.

Advertising