TUBULAR GAS FIRED PROPELLER

UNIT NUMBER DESCRIPTION

Digit

T X X X — 1 2 3 4 5 6 7 8 9 10

11

12

13 +

Item

Prefi

x

UT

CA FT

FM

GT

AL

GG

SV

MT

AS

(Internal use Only)

1,2 - Unit Type [UT]

TF -

Tubular

Propeller

3,4,5 - Capacity [CA]

100 - 100,000 BTU/HR

125 - 125,000 BTU/HR
150 - 150,000 BTU/HR
175 - 175,000 BTU/HR
200 - 200,000 BTU/HR
250 -

250,000

BTU/HR

300 - 300,000 BTU/HR
350 - 350,000 BTU/HR
400 - 400,000 BTU/HR

6 - Furnace Type [FT]

A - Right Hand Access

7 - Heat Exchanger (Furnace) Material [FM]

1 - Standard (Aluminized) Steel

2 -

409

Stainless

Steel

8 - Gas Type [GT]

N -

Natural

Gas

P - Propane (LP) Gas

9 - Altitude [AL]

S -

0-4,999

ft.

T - 5,000-11,999 ft.
Note: Installations over 2,000 ft. require gas input deration in the fi eld.

Refer to unit installation instructions.

10 - Gas Control [GC]

1 - Single Stage Direct Spark

2 - Two Stage Direct Spark

3 - Electronic Modulation w/Room Sensing

6 - Electronic Modulation w/External 4-20 mA Input

7 - Electronic Modulation w/External 0-10 VDC Input

11 - Supply Voltage [SV]

1 - 115/1/60

5 -

230/3/60

2 - 208/1/60

6 -

460/3/60

3 - 230/1/60

7 -

575/3/60

4 - 208/3/60

Z -

Other

Note: Supply Voltage [SV] 2-7 include fi eld mounted step down transformer.

12 - Motor Type [MT]

1 - Open Drip Proof (Standard)
2 - Totally Enclosed

13+ - Accessories [AS]

FACTORY INSTALLED
M6 -
OSHA Type Fan Guard

P4 - Terminal Block Wiring
P6 - Summer/Winter Switch

S3 - 409 Stainless Steel Flue Collector
S5 - Stainless Steel Burners

All Field Installed Accessories are to be entered as a separate line item
using the catalog number which places “AS” as a prefi x. i.e. A7 becomes
AS-A7.

FIELD INSTALLED (AS-_____)
A7 -
High Pressure Regulator
A7-1/2-1 - Regulator for 0.5-10 PSI
A7-3/8-1 - Regulator for 10-20 PSI
A7-5/16-1 - Regulator for 20-35 PSI

G1 - 1-Stage T87K Mercury Free Thermostat w/Subbase Kit
G2 - 1-Stage T87K Mercury Free Thermostat w/TG511A Guard Kit
G3 - 1-Stage T834N Mercury Free Thermostat/Fan Switch
G5 - 2-Stage TH5220D Mercury Free Thermostat w/Subbase
G6 - Locking Thermostat Cover
G8 - 1-Stage T6169C Line Voltage Thermostat w/Subbase
G9 - 1-Stage T822K Mercury Free Thermostat

M2-2 - 5" Vent Cap (Unit Capacities [CA] 100-250)
M2-3 - 6" Vent Cap (Unit Capacities [CA] 300-400)
M7 - 2 to 4 Point Suspension Kit

P5 - 24V SPST Relay-Specify Purpose

X2 - 30 Degree Downturn Nozzle
X3 - 60 Degree Downturn Nozzle
X4 - 90 Degree Downturn Nozzle
X5 -

Vertical

Louver

Kit