7 TROUBLE SHOOTING GUIDE

Symptoms

Probable Cause

Recommended Action

Pump will not start.

Electrical supply.

Check power supply.
Check fuse (see fuse section).
Check circuit breaker is set.
Check wiring connections.

Pump Jammed.

If motor ‘Buzzes’ switch off power and contact Stuart Turner.

Recommended static inlet/outlet
heads exceeded.

Re-position pump (see pump location section).

No flow.

Insufficient gravity flow to start the pump (must be at least
1 l/min.

Internal motor thermotrip
activated.

Wait for thermotrip to auto-reset and check that duty point and
run time is within specification (see technical specification).

Reduced/intermittent flow.

Incorrect or no anti-aeration
flange fitted

Check that the installation complies with installation
instructions.

Incorrect pipe sizes.

Check for correct pipe sizing, see Page 6 - Section 2.19.

Blocked inlet filters.

Clean inline strainer.

Air in system.

Run system on full hot for several minutes. Check that vents
are fitted as detailed in instructions.

Hot water temperature set too
high.

Reduce cylinder stat setting to 60

o

C max.

Blocked shower head spray
plate

Clean in accordance with manufacturers instructions.

No hot water.

Air locked water feed.

Vent hot water pump of air.
Check cold feed to hot water cylinder.
Check water level in cold water tank and that all stopcocks
and isolating valves are open.

Heat source not operating.

Check boiler is switched ‘on’.
Check cylinder thermostat.
Check immersion heater.
Check cylinder contains hot water.

All hot water has been used.

Check tank volume is adequate.

Faulty thermostatic mixer valve.

Consult makers instructions.

Pump runs on with outlets
closed.

Leak in system.

Check tap washers, w/c valve washers, pipe joints.

Damaged reed switch, P.C.B.

If pump continues to run, this indicates a closed circuit in
either the flow switch reed, or P.C.B. in the terminal box.
Contact Stuart Turner.

Jammed flow switch.

Remove outlet hoses and check that flow switch sits in lowest
position. Check float for free movement.

Flexible hose leaks

Not fitted correctly.

Check that the hose is pushed firmly onto the pump inlet/
outlet connections and pipework.

Damaged ‘O’-rings.

Check copper pipe ends are cleanly cut and deburred.