Hot water connection:
2.26

Hot water cylinder or storage tank: When a hot water cylinder or storage tank

is used, ensure the pipework size from the cold water storage to the hot water

storage is of adequate size and a minimum of 28 mm.

2.27

Hot water supply: The pump must be supplied with a dedicated feed direct

from the hot water cylinder or storage tank which should be via a secondary

dedicated tapping (see Fig. 4).

Do not connect to the mains.

2.28

Location: The pump must, for optimum performance, be sited as close as

possible to and never more than 4 metres from the HOT WATER cylinder. The

pump should always be sited BELOW the HOT WATER take-off from the cylinder.

2

LOCATION - HOT WATER INSTALLATION

Fig. 3

Hot water
pump

Fig. 4

Factory installed
secondary tapping with
28 mm.

Static inlet pressure

Min. 1 m

Max. 10 m

Static outlet pressure

12 m