7.12

Environment Protection: Your appliance contains valuable materials which can

be recovered or recycled.

At the end of the products’ useful life, please leave it at an appropriate local civic

waste collection point.

7.11

Flow Switch Circuit Test:

1. First confirm visually that the flow switch reed clamp have not been dislodged

during handling or installation. The clamp must be fully located within the flow

switch body groove as shown.

2. To carry out the following test you will need to obtain a magnet, a typical fridge

magnet

is

suitable.

3. Ensure the power supply is switched on.

4. Position the magnet directly in front of the reed clamp as shown. If pump

does not start, then slowly move the magnet up and down to a position that

exceeds the extent of the reed clamp. The pump should instantaneously

start at some point during this extent of movement. If this does not happen,

this indicates a possible fault with the reed switch or the P.C.B which is

located within the terminal box. These should be checked electrically.

Consult Stuart Turner for further instructions.

Fig. 10

Groove

Body

Reed Clamp

Magnet