background image

NEXO

154 allée des Erables - BP 50107 - 95950 ROISSY CDG CEDEX – France - Tel : +33 (1) 48-63-19-14

Fax : +33 (1) 48-63-24-61 - Email :

[email protected]

- Web :

http://www.nexo-sa.com

-

S.A. au capital de 1.003.000 €. R.C

Bobigny 317 272 540 - SIRET 317 272 540 00038 APE 323Z

13/38

Audience

Seated is 1.20 meter height mapping

Standing is 1.60 meter height mapping

No audience disables acoustic computations on selected plane, however, plane is still be displayed
in Venue (typically, ceilings, walls).

Disabled disables both display and computations (this feature allows to enter various configurations
in the same venue file)

Annotation

Annotation is Plane name

Vertex 1 to 4

Vertex 1 to 4 are to enter 4 plane corners coordinates. When double-clicking on selected vertex,
following Input Window appears:

This window allows to enter X,Y and Z vertex coordinates, and to eventually rotate (around origin) or
offset defined plane.

Values must be entered P1 to P4 going counter-clockwise.

If vertexes are entered in the wrong order (ie clockwise), no values will be displayed in
Cluster Pressure Plot. These planes can be easily inverted with the “Invert Plane” function.

Reversed planes can be easily identified as being white when seen from top (instead of
grey).

Menu

Menu opens below selection (also available on right-mouse click on a plane)

Edit Venue (3D Mode)

Opens Edit Vertices Window