Nexo GEO D User Manual

Page 38

Advertising
background image

NEXO

154 allée des Erables - BP 50107 - 95950 ROISSY CDG CEDEX – France - Tel : +33 (1) 48-63-19-14

Fax : +33 (1) 48-63-24-61 - Email :

[email protected]

- Web :

http://www.nexo-sa.com

-

S.A. au capital de 1.003.000 €. R.C

Bobigny 317 272 540 - SIRET 317 272 540 00038 APE 323Z

38/38

Cluster Dimensions and Weight

-

Cluster Type : as in Acoustic Page

-

GEO Quantity: as in Acoustic Page

-

CD18 Quantity: as in Acoustic Page

-

Bumper Angle: Angle in relation to Horizontal Line, CCW.

- Lower

Cabinet

Angle;

-

Cluster Height: Overall Height including rigging accessories;

-

Cluster Width: Overall Width including rigging accessories;

-

Cluster Depth: Overall Depth including rigging accessories;

-

Rear Rigging Point Height: Rear Bumper Rigging Point height referenced to Z=0;

-

Front Rigging Point Height: Front Bumper Rigging Point height referenced to Z=0;

-

Lower Cabinet Height: referenced to Z=0;

-

Distance between rigging points: horizontal distance from Rear to Front Bumper Rigging Points

-

Gravity Center to Front Rigging Point: horizontal distance from Gravity Center to Front Rigging
Point (must be positive and less than distance between rigging points, turns red if gravity center
off rigging points, turns orange if 5% to the limits)

-

Gravity Center to Rear Rigging Point: horizontal distance from Gravity Center to Rear Rigging
Point (must be positive and less than distance between rigging points, turns red if gravity center
off rigging points, turns orange if 5% to the limits)

-

Clearance from Front Rigging Point: minimum free space required ahead of Front Rigging Point

-

Clearance from Rear Rigging Point: minimum free space required behind Rear Rigging Point

-

Cluster Weight: total cluster weight including rigging accessories

-

Weight on Front Rigging Point: must be positive and less than total Cluster Weight (turns red if
gravity center off rigging points, turns orange if 5% to the limits)

-

Weight on Rear Rigging Point: must be positive and less than total Cluster Weight (turns red if
gravity center off rigging points, turns orange if 5% to the limits)

Advertising
This manual is related to the following products: