It is essential to execute all these check steps prior to perform a sound check on the “front end” to the
system. Following this checklist step by step will prevent many troubles and will save time in the end.

6.1 Are the NX242 Digital TDcontrollers properly configured?

IMPORTANT

If you must change any of the parameters listed above, make sure that you use the same
values on all NX242’s.

6.1.1 NX242 Load 2.13 and below

Freq. Band Gain Global Gain Amp Power Delay Sense Gain Array EQ Headroom

HF

32 dB

0 dB

1350 Watts

0 ms

0 dB

0 dB

5 bars

LF (rear)

32 dB

0 dB

2600 Watts

0 ms

0 dB

0 dB

5 bars

MF/LF (front)

32 dB

0 dB

2600 Watts

0 ms

0 dB

0 dB

5 bars

CD18 Sub

26 dB

0 dB

2000 Watts

0 ms

0 dB

0 dB

5 bars

6.1.2 NX242 Load 2.14 and above

Freq. Band Gain Global Gain Amp Power Delay Sense Gain Array EQ Headroom

HF

26 dB

0 dB

1350 Watts

0 ms

0 dB

0 dB

5 bars

LF (rear)

32 dB

0 dB

2600 Watts

0 ms

0 dB

0 dB

5 bars

MF/LF (front)

32 dB

0 dB

2600 Watts

0 ms

0 dB

0 dB

5 bars

CD18 Sub

26 dB

0 dB

2000 Watts

0 ms

0 dB

0 dB

5 bars

6.2 Are the amplifiers properly configured?

IMPORTANT NOTE FOR BRIDGE MONO MODE OPERATING AMPLIFIERS

Bridged mono operating mode adds 6 dB voltage gain.
Phase relation from amplifier input to output 1(+) and 2(+) has to be checked.

6.2.1 NX242 Load 2.13 and below

Freq. Band

Mode

Gain Switch

Limiter

High Pass

HF Stereo

32

dB

None

None

LF (rear)

Bridged Mono

26 dB*

None

None

MF/LF (front)

Bridged Mono

26 dB*

None

None

CD18 Sub

Stereo

26 dB

None

None

6.2.2 NX242 Load 2.14 and above

Freq. Band

Mode

Gain Switch

Limiter

High Pass

HF Stereo

26

dB

None

None

LF (rear)

Bridged Mono

26 dB*

None

None

MF/LF (front)

Bridged Mono

26 dB*

None

None

CD18 Sub

Stereo

26 dB

None

None

6.3 Are the amps and the NX properly connected?

Check that the sense LEDs on the NX242’s used for the full range Tangent Array Modules are
connected properly by applying a signal to the corresponding output and verifying that the correct
Sense LED illuminates.