INSTALLATION OF HEATED POLYCARBONATE ENCLOSURE STI-7510A&F-HTR, STI-7511A&F-HTR

All specifications and information shown were current as of publication, and are subject to change without notice.

7510A-HTR IS JULY 2007


IF CONDUIT HUB

IS NEEDED ORDER

SUB-6297B20

HUB KIT, GASKET

AND FASTENERS

NOTE:

SUB KIT IS

3/4 in. RIGID

DIE CAST

SUB-6297B20

3/4” NPT CONDUIT

HUB KIT (NOT

INCLUDED)

MOUNTING TABS & FASTENERS
19013 #10 x 1 1/2” PAN HEAD SCREW

07503 THUMB LOCK (SHOWN)
STI-7511F-HTR
18050 KEYLOCK STI-7510F-HTR

19033 PLASTIC ANCHOR

ILLUSTRATION 2

19013 #10 x 1-1/2 PAN

HEAD SCREW (4) PROVIDED

06297T MOUNTING

TAB (4) PROVIDED

19033 #10-12 PLASTIC
ANCHOR (4) PROVIDED

06297A-M BACK BOX

629721A FRAME GASKET

19002 #8-32 x 3/8”
PAN HEAD MACH SCREW
(4) PROVIDED

SUB-7500-HTR ASSEMBLY

19051 #8-32 x 3/8”
FLAT HEAD SCREW
(4) PROVIDED

19083 M-F #8-32 x 3/8”
STANDOFF (4) PROVIDED

*ADDITIONAL STANDOFFS MAY BE REQUIRED
WHEN USING A WATERTIGHT CONDUIT HUB.
19083 M-F #8-32 x 3/8”
19093 M-F #8-32 x 1-1/2”
19056 M-F #8-32 x 3”
(NOT INCLUDED)

18021 3/4” NPT
WATERTIGHT CONDUIT
HUB (NOT INCLUDED)

07503 THUMB LOCK - STI-7511A-HTR
18050 KEY LOCK - STI-7510A-HTR

629723 COVER GASKET

DRILL (4) 1/4” DIAMETER

HOLES 1 1/4” DEEP



BACK BOX

ILLUSTRATION 1

HEAT

ON

POWER

REMOVE

H

INSTALLATION INSTRUCTIONS

1. Remove heater plate assembly (Illustration 1) from back box by

removing 4 flat head screws and set aside.

2. Mount back box and cover assembly in desired position. With

hinges horizontal or vertical, insert the (4) mounting tabs into
the back box slots (see Illustration 2). Mark and drill (4) 1/4”
diameter holes 1 1/4” deep. Insert plastic anchors and screw
back box to wall with (4) #10 x 1 1/2” screws.

3. Route wires for heater and appliance into back box through

conduit or small hole properly sealed.

HEAT

ON

POWER

5.59 in.

(142mm)

7.53 in.(191mm)

4.04

1.88

Electronic warranty form at www.sti-usa.com/wc14