Controller status (redundant system), Fan led, Temperature status led – Brocade Mobility RFS4000 Controller Installation Guide (Supporting software release 4.3.0.0 and later) User Manual
Page 19

System status LEDs
3
Brocade Mobility RFS4000 Controller Installation Guide
9
53-1001933-02
Controller status (Redundant System)
Fan LED
Temperature status LED
System status 1
LED
System status 2 LED
Event
off
off
power off
green solid
off
redundant system normal operation
green blinking
green solid
redundant system failed over and adopting
ports
green blinking
alternating green blinking &
amber blinking
redundant system not failed over.
Fan LED
Event
off
system off / POST start
green blinking
POST in process
green solid
all system fans normal operation
amber solid
redundant cooling failure system operational
amber blinking
system cooling failure - system will be held in reset until the issue
is resolved
Temperature LED
Event
off
system off
green solid
ambient inlet temperature is within specified operating limit
amber solid
ambient inlet temperature is near the maximum operating
temperature. during controller start up this LED will be lit solid
amber. this is normal behavior and does not indicate an error.
amber blinking
ambient inlet temperature is above the maximum specified
operating temperature. system will be held in reset until the issue
is resolved
MobilityRFS4000ControllerInstallGuide.book Page 9 Friday, June 10, 2011 1:32 PM