Step 1, Installation steps – Burcam 506721 CONVERTIBLE C.I. JET PUMP 3/4HP 115/230V User Manual

Page 3

Advertising
background image

3

APPLICATIONS

• This pump is designed for shallow well installation

for water level up to 25 feet, with injector screwed

on pump body; or for deep well installation for water

level up to 80 feet, with 2 pipes and injector down in

the well.

• CAPACITY AT 30 PSI

:

SHALLOW WELL

DEEP WELL

1/2 HP 3/4 HP

1/2 HP 3/4 HP

5’ 585 660

10’ 510 525

30’ 520 550

15’ 440 450

40’ 420 450

20’ 330 350

50’ 330 350

25’ 220 250

80’ 150

75

US GPH

US GPH

FEATURES

• High performance brass impeller.

• Industrial motor totally enclosed, fan cooled.

• Full time connected run capacitor, to eliminate

starting wear vs regular motor.

• Thermal and overload protection.

• Built for a continuous use.

• 1/2 HP, 115 VCA, 60 Hz, 8A

, (

17A

at start ).

• 3/4 HP, 115 VCA, 60 Hz, 9A

, (

19A

at start ).

Friction loss in pipe not included.

INSTALLATION STEPS

We recommend that you install your pump in a clean and dry location where there is adequate room

for servicing at a later date. Protection from freezing temperatures and good ventilation should be

considered as well, to provide the pump an environment for long life. Locating the pump as close as

possible to the water source will reduce friction losses encountered in the suction pipe.
Friction losses in the suction pipe must be taken into consideration when the horizontal offset is greater

than 50 feet. The suction pipes should be increased from 1” to 1 1/4”. This will reduce friction losses and

allow the pump to give maximum performance.
A new well should be checked to determine that it is free from sand. Sand will damage the seal and the

impeller. Have your well driller clean the well before your installation.
Never run the pump dry. Damage to the seal may occur. Fill pump body and suction pipe with water

before turning on the power.
THE RUN OF HORIZONTAL PIPE FROM THE TOP OF YOUR WELL INTO THE HOUSE,

WHERE YOUR PUMP WILL BE LOCATED, MUST BE INSTALLED IN A TRENCH, BELOW THE

FROST LEVEL OF YOUR AREA.

STEP 1

For installation where the water level is between

0 to 25 feet (0

to 7.5 m) deep from the pump location, your injector as been pre-

installed in manufacture with the venturi 506308.1. It is a shallow

well application mode. Only one (1) pipe is required to pump from

this level. The injector is fixed directly to the pump body (see on page 4).

However, if the pumping level is between 25 to 80 feet (7.5 to 24 m)

deep from the pump location, you will need to remove the injector

from the pump body, unscrew the nozzle venturi pre-installed and

replace it by the enclosed nozzle/venturi 506308.2. This is a deep

well application mode. The injector will be installed into the well with

two (2) pipes fixed to the pump body (see on page 5).

For deep well application mode, 25’ to 80’.

For shallow well application mode, 0’ to 25’.

506308.1

506308.2

6 1/8" (156mm)

8" (203mm)

0.26"

7mm

0.195"

5mm