Actron CP9190 User Manual

Page 143

Advertising
background image

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 6 – 21

Ford Historic (OBD I) Diagnostics

6

4. Wiggle Test instructions.

•Use the

LEFT or RIGHT arrow key to view wiggle test

instructions or not.

•Press

ENTER to continue.

✓

Instructions are available for
viewing. The default is Yes. If No is
selected, the test begins to
initialize.

✓

If Yes is selected, the following instructions appear.

❒

Gently tap and shake the sensor.

❒

Wiggle the sensor connectors.

❒

Twist and shake the wiring between the sensor and the PCM.

5. Start KOEO/KOER Wiggle Test.

•Press

ENTER.

✓

After the 10-second initialization
period, the Scan Tool is ready for
the Wiggle Test. Locate the
suspect sensor or circuit
according to the above
instructions.

✓

If a fault is detected, the Scan Tool
beeps and displays a FAULT
PRESENT message. A DTC(s) is
stored in the PCM and the Scan
Tool.

6. Return to On Demand Test

Menu.

•Press

BACK

.

View instructions

for wiggle test?

<Yes>

No

KOEO Wiggle Test

Wiggle Test Running.

Status:

*** Circuit OK ***

KOEO Wiggle Test

Wiggle Test Running.

Status:

*** Fault Present ***

KOEO Wiggle Test

Advertising