Choosing a site, Housing your davey pump, Power connection – Davey HM Series Electric Pumps User Manual

Page 3

Advertising
background image

Choosing a Site

Choose a site with a firm base as close to the water

source as possible with correct power supply. Make sure

your pump is always connected to an adequate, reliable

source of clean water.

Housing your Davey Pump

To protect your pump from the weather, make

sure the pump house is both water proof, frost

free and has adequate ventilation.

The pump should be mounted on a firm base

allowing for drainage, to avoid damage to

flooring etc., that over time may occur from

leaking pipe joints or pump seals. Do not mount

the pump vertically. Never place flammable

materials on or near your pump.

Power Connection

Single Phase

The single phase models which are supplied with a 10 amp plug may be plugged

into a standard 10amp outlet. Model with the special 15 amp power plug may only

be used with the appropriate 15 amp 220/250V power outlet (15 amp power outlets

are usually specially provided by an electrician).

Always ensure that the earth conductor in the lead is connected to a good earth.

All single phase Models have automatic re-set thermal overload protection built

in, i.e. should overload on motor cause thermal to open circuit and switch motor

off, it will automatically re-set and switch motor on when motor has cooled down

sufficiently, usually within a few minutes.

The electrical connections and checks must be made by a qualified

electrician and comply with applicable local standards. Poor installation

or poor power supply may even result in electrical fires!

Connect lead to power supply designated on pump label, do not use

long extension leads as they cause substantial voltage drop, poor pump

performance and may cause motor overload.

NOTE:

1. Ensure motor is connected to power supply specified on nameplate.

2. Avoid long extension leads as they can cause substantial voltage drop

and operating problems.

3. Although the Davey electric motor is specifically engineered to perform

on a range of power supply voltages, malfunctions or failure caused by

adverse voltage supply conditions are not covered under guarantee.

In accordance with AS 3350.2.41 we are obliged to inform you that this

pump is not to be used by children or infirm persons and must not be used

as a toy by children.

10

3

*NOTE “MOTOR PROTECTION DEVICE” :

For protection, the Davey pump motor is fitted with an automatic reset

thermal overload, constant tripping of this overload indicates a problem

e.g. low voltage at pump, excessive temperature (above 50°C) in pump

enclosure.

WARNING: When servicing or attending pump, always ensure power is

switched off and lead unplugged. Electrical connections should be serviced

only by qualified persons.

WARNING: Automatic reset thermal overloads will allow the pump to restart

without warning. Always disconnect the pump motor from the electrical supply

before maintenance or repairs.

WARNING: Do not use hydrocarbon based or hydrocarbon propelled

sprays around the electrical components of this pump.

Care should also be taken when servicing or disassembling pump to avoid

possible injury from hot pressurised water. Unplug pump, relieve pressure

by opening a tap on the discharge side of the pump and allow any hot water

in the pump to cool before attempting to dismantle.

IMPORTANT:

DO NOT USE petroleum based fluids or solvents (e.g. Oils, Kerosene,

Turpentine, Thinners, etc) on the plastic pump components or seal

components.

Advertising