Choosing a Site

Choose a site with a firm base and as close to the water source as possible with

correct power supply. Make sure your pressure system is always connected to an

adequate, reliable source of clean water.

Housing your Davey Pressure System

To protect your pressure system from the weather, make sure the pump house is

both water proof, frost free and has adequate ventilation. The pump should be

horizontally mounted on a firm base allowing for drainage, to avoid damage to

flooring etc., that over time may occur from leaking pipe joints or pump seals. Do

not mount the pump vertically.

4

9

WARNING: Some insects, such as small ants, find electrical devices

attractive for various reasons. If your pump enclosure is susceptible to

insect infestation you should implement a suitable pest control plan.

Maintenance

The only regular attention your new pressure system may require will be if you

have used an additional pressure tank. You will need to check the pressure tank’s

air charge every 6 months. This can be checked at the air valve with a tyre gauge.

Do not charge tank to a higher pressure than 135kPa for HP models or 195kPa for

HS models.

To check air pressure in tank:

1. Switch off pump.

2. Open outlet nearest to pump to release water pressure.

3. Charge tank to required pressure using air pump and check with tyre gauge.

4. Switch on.

5. Close outlet.

WARNING : Under no circumstances should the Presscontrol be

disassembled. Failure to observe this warning will expose persons to

the possibility of personal injury and may also result in damage to other

property. Do not dismantle, no user serviceable parts, spring under

pressure.