Pipe connections, Extra draw-off capacity – Davey HP, HS & HM Pressure Systems with Presscontrol User Manual

Page 6

Advertising
background image

6

7

Installations with flooded suction require a gate or

isolating valve so water supply can be turned off for

pump removal and servicing.

For Automatic Pressure

Pumps Installed with a Mains

Pressure Hot Water System

To protect your system from damage caused

by back pressure from hot water systems. You

should always have installed on the hot water

inlet an approved non-return valve.

Connection of Mains Scheme or Town Water

Supply to either Suction or Discharge of Pumps &

Pressure Systems

Most Water Supply Authorities have strict regulations regarding direct connection of

pumps to mains water supplies. In most cases an isolating tank is required between

mains supply and pump. Davey also recommend this method. Directly applied

mains pressure can exceed pump operating pressure and damage pump.

Davey Water Products Pty Ltd

can not accept responsibility

for loss or damage resulting

from incorrect or unauthorised

installations.

Abrasive Materials

The pumping of abrasive materials will

cause damage to the pressure system

which will then not be covered by the

guarantee.

NOTE: Always ensure hot

water systems are installed in compliance with manufacturers

recommendations and in accordance with all local regulations.

Pipe Connections

For best performance use P.V.C.

or polythene pipes at least the

same diameter as the pump’s

inlet and delivery outlet openings.

Larger diameter pipe may be

used to minimise resistance

to flow when pumping longer

distances.

Use unions at pipe connections to enable easy removal

and servicing. Use sufficient tape to ensure airtight seal

and hand tighten only. To prevent strain on pump threads

always support heavy inlet and outlet pipes. If there is

a likelihood the water supply may contain solid particles

such as pieces of plant or vegetable matter, a filter should

be installed before the pump to avoid blocking of water

ways. Lay suction pipe at a constant gradient to avoid air

pockets which may reduce pump efficiency.

Extra Draw-off Capacity

The “Presscontrol” has an inbuilt accumulator which will accommodate small

leaks. In some applications it may be appropriate to install additional accumulator

(Supercell pressure tank) capacity. These applications includes:

• Long suction lines (see Suction Lines / Lift)

• Low flow appliances connected to the pump, such as evaporative air

conditioners, slow filling toilet cisterns.

Any additional accumulators can be installed downstream of the controller (ie.

between the controller and the first outlet).

NOTE: Suction leaks are the largest cause of poor pump performance and

are difficult to detect. Ensure all connections are completely sealed using

thread tape only.

DO NOT USE THREAD SEALING COMPOUNDS, HEMP OR PIPE DOPE!

Do not use pipe thread sealing compounds on any part of this pump. ONLY

use Teflon sealing tape.