1. Check for any damage to the D-ring Extender. Inspect all metal parts for cracking,

bending, burrs or deformation of any kind. Ensure that there are no missing parts. If any
of these conditions exist, remove from service immediately and replace.

2. Inspect all metal surfaces for evidence of excessive corrosion. Light surface corrosion

should be removed with steel wool. If excessive corrosion exists, remove from service
immediately and replace.

3. Inspect the D-ring Extender for build-up of any surface contamination such as paint,

grease, oil, dirt or any other foreign substance which may inhibit the operation of an
mechanical parts.

4. Check the function of any and all mechanical parts such as the gate and latch or keeper

on the snap hook or rebar hook. Ensure that the gate closes and locks securely and
automatically and that the gate and latch or not bent, dented cracked or damaged in any
way. Ensure that all rivets are seated and do not exhibit cracks or any other visible form
of damage. Any of these elements should be capable of being operated or adjusted with
a minimum of effort. If there is any mechanical deficiency, immediately remove this D-
ring Extender from service and have it replaced.

5. Inspect the webbing for cuts, tears, fraying or damage from abrasion. Ensure that it is

free of contamination from excessive dirt, soil, paint, petroleum products or other
contaminants or substances.

6. Check stitch locations for torn or loose threads, missing stitches and signs of any stress

or strain.

7. If you know or suspect that this D-ring Extender has been used in a fall, remove it from

service immediately and have it replaced.

8. Inspect the labels and ensure that they are present or legible. Re-familiarize yourself

with any warnings or instruction on the labels. If the labels are missing or illegible,
remove the D-ring Extender from service and have it replaced.

9. The results of semi-annual Competent Person inspections should be recorded in section

8.3 of this manual.

10. If this D-ring Extender fails any part of this inspection, be sure to remove it from service

immediately and have it replaced.



8.3: Mandatory Semi-Annual Inspection

ANSI Z359.1-2007 requires that all fall protection equipment be inspected by a competent
person other than the user at least once each year. FallTech strongly encourages that all fall
protection equipment be inspected by a competent person other than the user at least once every
six months.

This inspection should be noted in the inspection log below, along with any deficiencies. This
inspection should also be used as an opportunity to counsel any authorized persons with respect
to any deficiencies that they may have failed to note in their daily inspections.