FallTech Web SRL’s User Manual

Page 13

Advertising
background image

25

function and to ensure that the equipment is in serviceable
condition. Failure to do so may result in serious injury or death.

FallTech requires that the following steps be taken during each
inspection prior to use of this Web SRL:

1. Check the load-indicating swivel carabiner at the attachment

end of the SRL. If the red indicator is visible between the swivel
mechanism and the carabiner body, then the SRL has been
subjected to fall arrest forces and must immediately be removed
from service. If the model you are using does not have a load-
indicating carabiner, ensure that the indicator stitch located on
the webbing between the attachment end connector and the SRL
housing is intact. If it is not, remove the SRL from service
immediately.

2. Pull approximately 2 - 4 feet of line out of the unit and hand-lock

the unit by pulling sharply on the line. Repeat this procedure
three times – if the unit does not lock up each time, or if it “slips”
after locking up, immediately remove the unit from service and
have it replaced.

3. Ensure that the SRL cable extends and retracts freely.
4. Pull the complete length of webbing out of the unit and look for

kinks, knots, fraying, surface contamination, paint build-up or
evidence of damage from an electrical arc or welding splatter.
Surface contamination should be removed with a damp rag and
a simple solution of soapy water. Any damage to the webbing
may indicate an unsafe condition, and the SRL should be
removed from service.

5. Inspect the exit bushing for excessive wear, sharp edges or

burring. If these conditions exist and are beginning to cause
damage to the webbing, remove the SRL from service.

6. Inspect the carabiner/snap hook gates at the anchorage and

attachment ends of the product to ensure proper locking
function. If the gates do not close and lock automatically due to
the presence or build up of grease, dirt, mud, paint or any other
substance or condition, then the SRL should be removed from
service.

7. Check the SRL housing for signs of cracking or denting. Also

check for loose screws and any bent, cracked or damaged parts.
If the SRL exhibits any structural damage, then remove it from
service immediately.

8. Ensure that all metal components are free of corrosion, and that

there is no evidence of cracking, denting or distortion.

9. Ensure that all labels and warnings remain attached and that

they are legible.

26

10. If the SRL fails to pass inspection on any of these points, or if

there is any doubt as to whether it is in proper working order,
immediately remove it from service.





8.3: Mandatory Semi-Annual Inspection

ANSI Z359.1-2007 requires that all fall protection equipment be
inspected by a competent person other than the user at least once each
year. FallTech strongly encourages that all fall protection equipment be
inspected by a competent person other than the user at least once every
six months.

This inspection should be noted in the inspection log below, along
with any deficiencies. This inspection should also be used as an
opportunity to counsel any authorized persons with respect to any
deficiencies that they may have failed to note in their daily inspections.


Inspection Log

FallTech Contractor Series Cable SRL


Model #:_______________

Serial #:_______________

Mfg. Date:_____________

Advertising