27

Inspection Log

FallTech Contractor Series Cable SRL


Model #:_______________

Serial #:_______________

Mfg. Date:_____________

Inspection

Date

Inspector Comments Pass/Fail Corrective

Action to be

Taken

Approved

By

28


Section 9: Maintenance and Storage

The service life of your FallTech Web SRL will depend on two factors:
The environmental conditions of your working environment along with
proper care (specifically, maintenance and storage).

Keeping the SRL clean and free of contaminants will greatly increase
the service life and will ensure that the SRL will be in proper working
order in the event that you need it to arrest a fall. The following steps
should be taken periodically:

1. Using a damp rag and a mild soap and water solution, wipe

down the SRL housing to remove soil and surface contaminants.
Ensure that the labels are legible at all times.

2. Use a slightly damp rag and a mild soap and water solution to

clean the webbing element of the SRL. Allow it to air dry.

3. Use a damp rag to clean the surfaces of any connecting

hardware.

4. If there is an excessive build up of paint, oil, dirt tar or other

contaminants that cannot be removed, remove the SRL from
service and have it replaced.

5. Store in a cool, dry location away from direct sunlight and where

it will not be exposed to chemical vapors.

6. This SRL should be hung on a rack or a peg or stored flat on a

shelf, stacked no more than three high.

7. Do not throw the SRL into a pile or a locker or storage box, as

this may damage the housing.


FallTech Web SRL’s do not require recertification . Provided your
SRL passes inspection, has been maintained and is in serviceable
condition, there is no need to send it in. If your SRL is in need of repair
or you are concerned about its condition, return it to the place of
purchase to arrange an inspection and/or repair through an authorized
service center. For further details, contact FallTech.