Hired-Hand Universal Ray Tube Heaters: AG1 Series User Manual

Page 16

Advertising
background image

Does the heater

stay ON until a call

for heat ends?

16

4.0

Troubleshooting Guide

Continued from page 14.

AG1

Series

Does the

burner ignite?

Test for 120V at valve opening period (usually 30 to 45 seconds

after power to heater). Is there 120V to valve for 8 seconds?

Replace circuit board and/or wiring harness.

Does the burner

stay on?

Is the ball valve

to the heater in

the ON position?

Check to make sure gas pressure is within

minimum and maximum inputs, as indicated on

burner rating plate. Is gas pressure OK?

Does the burner stay on

for approx. 8 seconds

and then shut off?

Does the burner come

on and turn off

immediately (1 or 2

seconds)?

Check to make sure gas pressure

is within minimum and maximum

inputs, as indicated on the burner

rating plate. Is gas pressure OK?

Pressure

switch may

be faulty or

there is a

restriction in

the exhaust.

Troubleshooting ends

The heater can shut down due to:

• Improper grounding.

• High winds.

• Taking combustion air from the attic.

• Dirty environment.

• Improperly positioned baffles.

• Fluctuating gas pressure.

No

Yes

No

Yes

Yes

No

Correct problem.

Yes

Yes

Yes

No

Yes

No

Yes

No

Yes

No

Turn on.

Yes

Correct problem.

No

No

Advertising