Hired-Hand Universal Ray Tube Heaters: AG1 Series User Manual

Page 5

Advertising
background image

Model Number

Mounting

Angle*

Sides

Front

Behind

Top**

Below

AG1 (20, 30, 40) - 50 [N, P]

9

9

6

47

45°

39

8

10

47

with 1 side shield

29

8

6

47

with 2 side shields

9

9

6

47

20 ft. from burner

7

7

6

30

AG1 (20, 30, 40) - 60 [N, P]

9

9

6

47

45°

39

8

10

47

with 1 side shield

29

8

6

47

with 2 side shields

9

9

6

47

20 ft. from burner

7

7

6

30

AG1 (20, 30, 40) - 75 [N, P]

9

9

6

60

45°

39

8

10

60

with 1 side shield

29

8

6

60

with 2 side shields

9

9

6

60

20 ft. from burner

7

7

6

30

AG1 (30, 40, 50) - 100 [N, P]

14

14

6

66

45°

39

8

10

66

with 1 side shield

29

8

6

66

with 2 side shields

16

16

6

66

20 ft. from burner

7

7

6

30

AG1 (40, 50) - 125 [N, P]

20

20

6

76

45°

58

8

10

76

with 1 side shield

42

8

6

76

with 2 side shields

20

20

6

76

20 ft. from burner

7

7

6

30

AG1 (40, 50, 60) - 150 [N, P]

24

24

6

81

45°

58

8

10

81

with 1 side shield

42

8

6

81

with 2 side shields

23

23

6

81

20 ft. from burner

11

11

6

44

5

1.0

Safety • Clearance to Combustibles

Chart 1.1 •

Clearance to Combustibles in Inches (see Figure 1.1 for Mounting Angles)

Figure 1.1

Mounting Angles

0° Mounting Angle

45° Mounting Angle

0° Mounting Angle

with 1 Side Shield

0° Mounting Angle

with 2 Side Shields

Side

Side

Below

Top

Front

Behind

Front

Behind

Side

Side

AG1

Series

* Heaters mounted on an angle between 0° to 45° must maintain clearances posted for 0° or 45°; whichever is greater.

** Maintain a 10 in. (0° mounting angle) or 12 in (1-45° mounting angle) clearance from ceilings constructed of tri-ply

plastic or plastic fogger lines.

Top

Top

Top

Below

Below

Below