4801-5101

Rev

6-09

Page

10

of

26

Super Saver XL CE Heater

6. Gas/Air Requirements

Table 1: Gas/Air Requirements

Appliance Gas

Common

Inlet

Pressure

Operating

Orifice Dia. (mm)

Conversion Kit

Category Number

Name

(mbar)

Pressure

(mbar)

Below 610m

TO the stated Category

2H, 2E

G20

Natural Gas

20

9.45

9.15

6450-9085

2L

G25

Low Heat Value Nat. Gas

25 14.10 9.15

6450-9085

3B/P G30/G31 Butane/Propane

30/50

25.00

4.57

6450-9087

3P G31

Propane

37

25.00

4.69

6450-9086

Appliance

Gas Flow

Rate Combustion Air

Ventilation

CO

2

Limit Air

Cal. Value*

Category Number Required

(m

3

/hr) Provided (m

3

/h) Required (m

3

/hr) (MJ/m

3

)

2H,2E G20

6.28

m

3

/hr

60 1700 238

37.78

2L G25

7.31

m

3

/hr

60 1700 266

32.49

3B/P G30/G31

4.8

kg/hr

58

1700 160 125.81

3P G31

4.71

kg/hr

59 1700 115

95.65

Source: Adopted European Standard EN 437:1993

*Gross Cal. Values, 15°C (59°F ), 1013.25 mbar (406.78 in. w.c.)


7. Conversion To Other Gases

7.1 Tools

Required

Adjustable Wrench

Pipe Wrench

Pipe Sealant

Gas Leak Testing Solution



























Orifice

Burner

Gas Valve

Ball Valve

F

F

i

i

g

g

u

u

r

r

e

e

9

9