Gas valve
Shown in

“ON” position

C A U T I O N !

LIMITING EXCESS CARBON DIOXIDE (CO

2

)

In order to prevent hazardous accumulation of CO

2

gases, the heater must

operate ONLY in a properly ventilated room.

The Gas/Air Requirement table (Section 6) lists the minimum amount of fresh air required

for heater to limit CO

2

to safe levels.

Both installer and operator must ensure that the building’s ventilation rate never drops

below the noted limits.

5.2 Starting

Up

Adjust thermostat higher than house temperature. Allow 20 seconds for heater to ignite. On initial start
up or when heater has not been in service for some time, heater may require more than one attempt to

purge air and ignite heater. (IF HEATER FAILS TO IGNITE, REFER TO TROUBLE SHOOTING
GUIDE). Adjust thermostat to desired house temperature.









5.3 Shutting OFF Heater

Shut off main gas supply valve, close ball valve, and disconnect electrical power.