Nature Power True Sinewave Inverter 1000w/2000w User Manual

Page 6

Advertising
background image

 

Page 6

 

 

 

12V Battery Bank:

The use of deep cycle battery is highly recommended for power inverter application

For battery size, you need to identify how much you will be using them between charges.

Nature Power recommends you purchase as much battery capacity as possible. See more

on Battery Run time and Load in Section 4.

Fuse or Circuit Breaker:

DC-rated fuse or DC-rated circuit breaker connected along the DC positive line is required.

For 38210, 38310, select a fuse or circuit breaker with a minimum of 150 Adc

For 38215, select a fuse or circuit breaker with a minimum of 225 Adc

For 38320, select a fuse or circuit breaker with a minimum of 300 Adc

Based on the size of the battery bank chosen on the 12V Battery Bank above, determine the

overall short circuit current rating of the battery bank from the battery manufacturer. The fuse

or circuit breaker chosen has to be able to withstand the short circuit current that may be

generated by the battery bank.

Disconnect Switch:

Select a Disconnect Switch with the same or higher the rating of the selected fuse or circuit

breaker from the above.

The Disconnect Switch is used to disconnect the DC power between the power inverter and

the battery bank during service, maintenance or trouble shooting.

DC Input Cable:

Low resistance wire (copper) is required for all the DC connections between the inverter and

the battery bank.

For 38210, 38310, uses minimum #2 AWG wire with maximum cable length of 5 feet.

For 38215, use minimum #1/0 AWG wire with maximum cable length of 5 feet.

For 38320, use minimum #2/0 AWG wire with a maximum cable length of 5 feet.

Grounding Cable:

Use minimum #10 AWG wire. Make sure you install the proper fuse or circuit breaker in the DC

positive line. The unit is grounded through the ground stud of the unit located near the DC Input

terminal. Use crimp ring terminal (lugs) to connect the grounding cable to the stud.

Installing the Power Inverter System.

WARNING

:

Electrical Shock Hazard

The unit ‘On/Off’ switch does not disconnect the DC power from the battery. Use the DC

Disconnect Switch or disconnect the DC input cables connection to disconnect the DC

power from the battery before working on any circuits connected to the unit. Failure to

follow these instructions can result in death or serious injury.

Power Inverter Installation:

Choose an appropriate mounting location.

Power Inverter

(38210,

38215,

38310,

38320)

Disconnect

Switch

Fuse or Circuit

Breaker

12 V Battery Bank

(Charger system

sold separately is

required to charge

the battery bank

when battery is

discharged)

Pos +

Neg -

AC

&

USB

LOADS

Advertising