Danger, Caution – Nature Power True Sinewave Inverter 1000w/2000w User Manual

Page 7

Advertising
background image

 

Page 7

 

 

 

For indoor use, the orientation of the unit can be mounted in any direction except with the DC

Input panel facing downwards. This is to meet electric codes, so in case the unit gets fire, any

hot debris cannot fall to the floor through the fan holes.

For RV installation, the unit has to be mounted flat on horizontal surface.

Use mounting template below to mark the positions of the mounting screws.

Drill the 4 mounting holes and place the inverter in position and fasten the inverter to the

mounting surface.

Power Inverter Chassis Grounding Connection:

DANGER:

The Power Inverter’s chassis needs to be grounded properly. Never operate the

Power Inverter without it being properly grounded. Failure to do so will result in death or

serious injury.


Connect the grounding cable’s ring terminal to the unit ground screw.

Connect the other side of the cable to the common grounding point.

Power Inverter DC Input Connection:

CAUTION

: Reverse the DC Input terminal will damage the unit and cannot be repaired.

Damage caused by reverse polarity connection is not covered by the warranty.

Connect one end of the negative DC input cable to the Power Inverter DC negative terminal.

Connect the other end of the negative DC input cable to the battery negative terminal.

Make sure the Disconnect Switch is in the OFF position.

Connect one end of the positive DC input cable to the Power Inverter DC positive terminal.

38215 15.0“

38210 12.3”

6.

9”

38310 12.6”

38320 16.3”

38210 12.3”

38215 15.0”

38310 16.3”

38320 12.6

6.

9”

38320

6

.9

38310

9

.1

38310

6

.9

38320

9

.1

Advertising
This manual is related to the following products: