Unit operation – Nature Power True Sinewave Inverter 1000w/2000w User Manual

Page 8

Advertising
background image

 

Page 8

 

 

 

Connect the other end of the positive DC input cable to one of the terminal of the Disconnect

Switch.

Connect a DC input cable between the other terminal of the Disconnect Switch and one side

of the terminal of the fuse holder.

Connect a DC input cable between the other terminal of the fuse holder and the battery

positive terminal.

Install the selected fuse to the fuse holder.

Turn Disconnect Switch to ON position.

Remote Switch (optional) Connection:

Insert the Remote Switch to the RJ11 Remote Port located at the Front AC panel of the

Power inverter. Please note polarity. The part number is # RM1201-00 or # 30001.

Test the Power Inverter connection:

Turn unit on by pressing and holding the On/Off button on the main unit for about a second

until a beep sound occur. The ‘Status’ light turns on indicating the Nature Power Inverter is

ON. Check the digital display show measured battery voltage and output power alternatively.

Both AC output and 5V USB are now available.

Plug in a small AC load like a 40W table lamp or small appliance to the AC socket to verify

AC is available. If AC is not available, the GFCI may be tripped. Reset the GFCI by pressing

the ‘RESET’ button.

The unit is successfully installed and functioning properly.

Test the GFCI monthly:

Use the following instruction to perform a monthly test on the GFCI to ensure the GFCI is

functioning properly.

Turn unit on and plug a small AC load (40W light bulbs) to the GFCI.

Check the AC load is ON.

Press ‘Test’ button and observe a click sound. Check AC load is turned off.

Press ‘RESET’ button and check the AC load is back ON again.

4. UNIT OPERATION

WARNING:

RISK OF EQUIPMENT DAMAGE

For

38210, 38215: Do not plug surge-protected power bars into the unit’s 120 VAC outlets. The

surge protected components on the surge-protected power bar may not like the modified sine

wave output generate by the inverter.

Do not connect an AC power source like utility power or generator to the unit 120 VAC outlets.

Turn ON and OFF the 120 VAC and USB

Press and hold the “Power/Select” button for 1 second until a beep is sounded. Display will

show the measured battery voltage and output power alternatively. Status LED will turn

green. Both 5V USB and 120 VAC are available.

Press “Power/Select” button to turn unit off.

Remote ON /OFF (Optional)

If optional remote is used, the Remote ON/OFF momentary switch is connected in parallel

with the “Power/Select” button on the unit. Same procedure applies to ON and OFF the unit.

Understanding the Display & Status LED

Display:

’12.5’ Display shows measured battery voltage

‘0.80’ Display shows total output AC power in kW (800W as shown)

‘E01’ Display shows error or warning code. See trouble shooting section in details

Status LED:

Green: Unit operation is normal

Advertising