页 13, Operating statustable – Nature Power 2000W-48V Marine Grade Wind Turbine (70701) User Manual

Page 13

Advertising
background image

Operating StatusTable

Mode

Indicator Light

Status

Cause

Next Operation

Start/Restart

No light

Not generating power.
(Wind speed range:
0 to 3 m/s, 0 to 11KPH,
0 to 6.7MPH)

The power is off,
or the wind is
weak and the
rotor is rotating
below 420rpm or
the DPDT Switch
is on brake position.

Starts in normal
operating mode

Normal
operation

Solid green

Generating power.
(Wind speed range:
3 to 12 m/s,
11 to 43KPH,
6.7 to 27MPH)

When the rotor is
rotating at 0 to 999
rpm

Flashing green

Generating power at
controlled rpm. (Wind
speed range: 12 to 20
m/s, 43 to 72KPH,
27 to 45MPH)

The rpm is limited
to 1000 rpm.

Flashing red

Generating power at
controlled 600rpm.

Voltage
protection

solid red

Generating power at
controlled rpm.

When battery
voltage is full and
exceeds57.2V

Rotor stopped

Recovers to normal
operation when the
voltage drops below
53.2V

Flashing red

Temperature
protection

solid red

Rotor stopped

When the
temperature
of the alternator
cover exceeds
90°C,194°F
or the
temperature
sensor is damaged

Recovers to normal
operation when the
temperature drops
below 60°C, 140°F,
If it is not recovered
over one hour,
contact us

Other

On and off

Intermittent brake

Defective or loose
connection to the
battery

Check battery
connections, the
turbine brushes
and their tracks

11

•Type: We recommend the use of deep cycle batteries (particularly AGM)
to handle the deep charge/discharge cycles in the wind turbine system.
The deep cycle battery has less instant energy than the starting (cranking)
ones used on cars, but greater long-term energy delivery. A car battery will
not last as long when used for repeated deep charged/ discharged cycles.

9. Considerations when choosing Peripheral Materials/Devices

9-1 Batteries

Wind speed:
Over 20m/s,
72KPH, 45MPH

Recovers to normal
operation when
wind speed below
20m/s,72KPH,
45MPH

•Series/Parallel Connections: You have to connect 4 x 12V batteries in
series to get a 48V group. The batteries in series within a group have to

Advertising