The turbine (especially

its tail) is yawing

continuously

Swirling air because

of turbulence

Change the location and/
or increase the height of
the tower/mast. Same as
per (1) above.

Every time the rotor

shaft begins to spin, it

stops suddenly with a

strong brake action

Open circuit in the DC

connection between

the turbine and the

battery bank

Check for loose or open
connections in the
cables. Make sure the
DPDT blade switch is in
the ON position (neither
the open nor the brake
[short circuit] one).

The rotor remains

stopped even with high

wind speed condition

If the Indicator light is

solid red

The battery bank voltage
and/or the internal
temperature of the
turbine have reached
their highest (cut-out)
limit and the turbine
stops. The turbine will
resume normal operation
in an automatic and
unattended way. Wait for
the proper cut-in
threshold or reset the
unit disconnecting and
reconnecting the battery
voltage with the DPDT
switch

If the Indicator light is

off

Make sure the DPDT
switch is not in the Brake
(short circuit) position

There is some
mechanical problem
(rotor shaft bearings,
hub, internal stator and
rotor contact, internal
damage). The unit has to
be inspected

The turbine works at

controlled rpm often,
with the battery bank

voltage below the

normal maximum of

57.2 V

The Indicator Light status

is flashing red

Normal if within the ±7% of

tolerance in the battery

voltage threshold values

shown in the Operating Status

Table.

Excessive voltage drop through

the cables and/or related

connectors. Please check the

proper cable gauge vs. length

as per the cable gauge chart,

the related connectors and the

batteries’ posts

High resistance or loose
connection in the turbine’s
brushes and/or their tracks.
They should be inspected and
cleaned.

17