Post-processing and analysis tool sets, Serial analysis – Agilent Technologies 16700 User Manual

Page 64

Advertising
background image

64

Post-Processing and Analysis Tool Sets

Serial Analysis

Clock Recovery Algorithm
1. For analysis purposes the data is

captured in conventional timing
mode using the internal timing
analyzer clock as the clock refer-
ence. Set the sample period of the
timing analyzer to take four or
more samples for each serial bit.

2. The timing analyzer data is sam-

pled in the middle of each bit
according to the serial bit rate
defined in the clock recovery
window.

3. Data edges (transitions from 0 to 1

or 1 to 0 in the timing analyzer
trace) are used to resynchronize
the sampling.

To Acquire a Serial Bit Stream
without an External Clock
Reference . . .

...set the sample period of
your timing analyzer to take
four or more samples for
each serial bit.

...accept the “Samples”
default label or enter a new
label name.

...specify the embedded bit
time of the serial bit
stream.

...specify the incoming
signal’s data encoding
method, normal or NRZI.

How Clock Recovery Works

Embedded bit time

Incoming serial
bit stream

Timing analyzer samples
(with timing analyzer set
to take five samples for
each serial bit)

New “Samples”serial data

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

0

0

0

0

1

1

1

1

1

Resynchronize on edge

Figure 5.18.

Figure 5.19.