Description – Star Water Systems FB12DCC (Flint & Walling) User Manual

Page 2

Advertising
background image

2

© Copyright 2013. All rights reserved.

MODELS:

C

D

E

F

ITEM DESCRIPTION

QTY

4/96

thru

10/05

11/05

thru

9/10

10/10

thru

5/13

6/13

thru

Current

1

DC backup pump

1

010475

017198

017198

017198

2

Plastic battery box

1

005702

005702

005702

005702

3

DC control charger with terminals

1

152907

152907

152907

152907

4

“Off”/”On” float switch

1

017197

017197

017197

017197

5

1½" x 5" long PVC pipe nipple

1

005639

N/A

N/A

N/A

6

Check valve

(2) REV C - (1) REV D

005636

005636

019768

019768

7

Reducer hose coupling and clamp

1

30-0188

N/A

N/A

N/A

8

1¼" x 1" PVC reducer fitting

1

005642

N/A

N/A

N/A

9

1" pipe to hose adapter elbow

1

005643

N/A

N/A

N/A

10

1" hose coupling and two clamps

1

005703

N/A

N/A

N/A

11

1½" PVC pipe tee

1

005645

005645

005645

005645

12

1½" 90 degree PVC pipe elbow

1

005644

N/A

N/A

N/A

13

1¼" x 1¼" PVC coupling

1

009129

N/A

N/A

N/A

14

Pump mounting kit, includes brkt, S.S. worm

drive clamp, two #10-24 screws and washers.

1

005704

N/A

N/A

N/A

15

Cable tie

1

005868

N/A

N/A

N/A

16

Anchors, Wall

2

009691

009691

009691

N/A

17

Bracket, control mounting

1

007779

007779

007779

N/A

18

1½" x 1½" PVC coupling

1

N/A

009746

N/A

N/A

19

Clamp, H28 55 zinc-plated screw

1

012724

012724

012724

012724

20

Fuse, Agc - 15 amp

1

N/A

012352

012352

012352

The DC emergency pump system requires a good quality, 12

volt battery to obtain maximum pumping time during a power

outage. A deep-cycle, 12 volt, 105 amp-hour marine battery or

larger is recommended and will provide approximately 7½ hours

of continuous pumping time in a sump pump installation with 8' of

head pressure. In most installations the pump runs intermittently

and the battery life is extended accordingly. Batteries with top

terminals are recommended for ease of installation. These batteries

contain acid and proper precaution must be taken when handling.

Maximum battery size 13½" Length x 7" Width x 9½" Height.

DESCRIPTION

The DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or primary

pump failure. The DC pump, electronic controls and all the parts required for installation are included except the battery which

is supplied by the user. The system is designed for installation in sumps with minimum of 18" diameter and 24" deep. For 18"

x 22" applications, consult factory.

REPLACEMENT PARTS LIST

PERFORMANCE

BATTERY SELECTION

The DC pump performance with fully charged 12V battery

Discharge

Feet of head 5

10

15

17.5

Flow GPM

23

15

5 Shut-off

Head

The DC controller is equipped with a 10 amp charger for maintaining the battery in a ready state and recharging the battery

after use when AC power is restored. Time for recharge depends upon the amount of power consumed by the pumping cycle

during the AC power interruption. The pump may go back to the ready run position in a very short period of time. A completely

drained battery may require up to 24 hours for full recharge.

2

12 VOLT BATTERY

SUPPLIED BY USER

1

19

4

20

3

6

11

SK2981

Advertising
This manual is related to the following products: