TROUBLESHOOTING

Problem

Possible Cause

Corrective Action

Motor runs, but delivers

little or no water

1. Air locked pump

1. Normal delivery may resume if water

pump is started and stopped at one

minute intervals

2. Gas or air in well water

2. Connect hose to service valve. Run

water thru hose submerged in water

in clear jar. Observe for air bubbles

from hose outlet. If tank is standard

type, the air volume control may be

defective - replace; otherwise, have

well checked for proper water level

as pump may be drawing air. Lower

pump and/or correct well condition

3. Low water level in well or pumping too much

from well

3. Throttle pump with gate valve. Lower

pump setting if depth of well is

adequate

4. Defective or improperly installed check valve

4. Pump must be raised to replace or

reinstall correctly

5. Leak in drop pipe damaged section

5. Raise pump, check pipe for leak and

replace

6. Pump inlet screen blocked

6. Raise pump and clean screen. Verify

that well is clean. Reset pump at less

depth if possible

7. Worn pump

7. Pull pump and replace damaged

components

8. Broken pump shaft or motor shaft or worn

coupling

8. Pull pump, inspect shafts and

coupling for damage. Replace

defective components

Pump operates properly,

but won’t shut off

1. Pressure switch

1. Readjust switch to lower shut off

pressure setting, clean contacts or

replace switch

2. Low water level

2. Throttle pump outlet at gate valve

or readjust pressure switch to lower

shutoff pressure setting

3. Leak in drop pipe or worn pump

3. Throttle pump output at gate valve or

readjust pressure switch to lower shut

off pressure setting. If pump does not

shut off, pump must be raised and

defect repaired

Pump starts too often

1. Pressure switch

1. Readjust switch to wider operating

pressure limits; replace defective

switch

2. Air volume in tank incorrect

2. Check pressure in tank. Set at 2 lbs.

below turn on pressure of the pressure

switch. i.e. 30/50 pressure switch

should have tank pressure of 28 lbs.

3. Check valve defect or leak in drop pipe

3. Throttle pump output at gate valve. If

pump does not shut off, pump must

be raised and defect repaired