4a 4b – Star Water Systems Star 4in Sub Instr2&3-wire User Manual

Page 5

Advertising
background image

8

Copyright © 2014 Star Water Systems. All rights reserved.

9

Copyright © 2014 Star Water Systems. All rights reserved.

ELECTRICAL HOOkUP AT THE PUMP

INSTALLATION INSTRUCTIONS

5

Securing wires to pipe
5. Tape electrical cable to the pipe about every ten

feet. Use a minimum of two wraps of tape to

allow the cable to move slightly. Tape spliced

connections to the pipe to eliminate rubbing

against the well casing. A cable guard or plastic

zip ties may also be used.

(Fig 5)

Ground Wire Installation (REQUIRED)

DANGER: The green ground wire from Pump

motor must be connected to power supply ground

or fatal electrical shock may result.

LOWERING PUMP INTO WELL
CAUTION: if your pump depth will be 200 ft.

or more, you may want to consider contacting

a professional well pump installer. Piping

filled with water, along with the weight of

the pump, will be very heavy. Be sure to have

assitance during pump installation.
REMINDER
: Pump and all piping must be assembled

and securely connected before the assembly is

lowered into the well.
1. Tie one end of safety rope securely to pump safety

eyelet and the other end to the well cap. This is

your only security against losing the pump down

the well.

(Fig 1)

CAUTION: Be sure the top edge of the well

casing is perfectly smooth. Sharp or jagged edges

can cut or scrape the cable and cause a short.

Do not let the cable drag over the edge of the

well casing since this may cause damage to the

insulation.
2. Lower pump to approximately 20 ft. below

maximum drawdown of the water or a minimum

of 10 ft. off the bottom.

Do NOT set pump on

bottom of well.

(Fig 2)

Safety

Rope

Drawdown

Water Level

10 Ft. Min.

20 Ft.

Top of Well Screen

Bottom of Well

1

2

INSTALLATION

3. Use a pipe vise to prevent the pump and pipe

from dropping into the well.

(Fig 3)

4a. Pitless Adaptor Installation. Pitless adaptor

should be installed below the frost line, and on

the side of the well casing where the supply

line will run from well, in accordance with the

manufacturer’s instructions.

(Fig. 4a)

NOTE: Pitless adaptor models vary according to

each application.

4b. Well Seal Installation: After the pump assembly

is lowered into the well, mount the well seal

onto the well casing and tighten the four bolts

in the well seal evenly.

(Fig. 4b)

4. Add a well seal or pitless adaptor to allow for the

pipe to be connected to house service.

(Fig. 4)

3

IL1148

4a

4b

Pitless

Adaptor

Installation

Below

Frost Line

Well Seal

Installation

At Top of

Well Casing

OR

4

Advertising