Fuse Box

Outside

Faucet

Pump in

Well

Outside

Faucet

Pump in

Well

Drawdown

Water Level

10 Ft. Min.

20 Ft.

Top of Well Screen

Bottom of Well

WARNING: All electrical wiring or service

should be done by qualified electrician. Be sure to

test cable for continuity with an ohmmeter before

starting the pump.
1. All wells should be flushed clear before allowing

water into the house.

(Fig. 1)

2. Open an outside faucet and allow water to

run until water is clear of sand or any other

impurities. If an outside faucet is not available,

place softener in bypass position, remove aerator

from a high-flow faucet and allow water to run

until it is clear of impurities. Once clear, turn off

water flow, replace aerator and put softener back

into service position.

(Fig. 2)

CAUTION: Be sure you do not stop pump

before water runs clear. This may take several

hours. If pump stops with sand in it, it may lock.

3. If pump lowers water in the well far enough

to lose prime, either lower pump in the well (if

possible) or throttle (slow down) the discharge

of the well with the gate valve to match the

capacity of the well.

(Fig. 3)

NOTE: If the well is low capacity, use a low water

level control.

1

2

3

PRELIMINARY TEST RUN

PRESSURE TANk INSTALLATION

The purpose of the pressure tank is to allow a certain

amount of water to be used before the pressure

drops enough to cause the pump to start. Without

a pressure tank, the pump would start and stop

constantly, every time water is used.
NOTE: Use thread tape and thread paste on all

threaded connections.

1.

NOTE: Check the air pressure of the tank with

a tire gauge before the system is charged

with water. The pressure should be 2 lbs. less

than the low pressure cut in on the pressure

switch. For instance, for a 30-50 switch, set

the tank pressure at 28 lbs. or less. (

Fig. 1)

2. Apply five wraps of thread tape and thread

paste, insert a tank tee through the opening in

the bottom of the pressure tank, and tighten

securely. (

Fig. 2)

3. Connect a 3/4 in. fitting to the 3/4 in. opening

on the pipe tee. (

Fig. 3)

IL1153

Tape

1

2

3

IL1154

Glue

4

4. Connect a 3/4 in. pipe and union to the 3/4 in.

fitting. (

Fig. 4)