8100 u, Status code, Description – Triton 8100 User/Installation Manual User Manual
Page 104

M
ODEL
8100 U
SER
/ I
NSTALLATION
M
ANUAL
86
Diverter sensor not connected
Timing wheel sensor not connected
Exit sensor not connected
Reject sensor not connected
Extension sensor not connected
Extension door open
Extension main cable disconnected
12-volt supply low
12-volt supply high
24-volt supply low
24-volt supply high
Missing pick motor feedback
Missing solenoid feedback
Pick motor fuse blown
Transport motor fuse blown
H
ARDWARE
S
TATUS
C
ODES
Status
Code
0 x 4d
0 x 4e
0 x 4f
0 x 50
0 x 51
0 x 52
0 x 53
0 x 54
0 x 55
0 x 56
0 x 57
0 x 58
0 x 59
0 x 5a
0 x 5b
Description
Double detect (0) not connected
Width sensor (0) not connected (Tx)
Width sensor (0) not connected (Rx)
Double detect (1) not connected
Width sensor (1) not connected (Tx)
Width sensor (1) not connected (Rx)
Double detect (2) not connected
Width sensor (2) not connected (Tx)
Width sensor (2) not connected (Rx)
Double detect (3) not connected
Width sensor (3) not connected (Tx)
Width sensor (3) not connected (Rx)
0 x 41
0 x 42
0 x 43
0 x 44
0 x 45
0 x 46
0 x 47
0 x 48
0 x 49
0 x 4a
0 x 4b
0 x 4c