SECTION 2 SAFETY INSTRUCTIONS


2.1

INSTALLATION/MAINTENANCE SAFETY


Before starting or installing the dryer, be sure that all power to
the unit is off, valves are shut, and the air circuit is at
atmospheric pressure. DO NOT remove, repair, or replace any
component, control filter, or part, while the air circuit is
energized or under pressure. Turn off the main to the dryer
and de-pressurize the unit before starting installation or
maintenance procedures.

MANUFACTURER WILL NOT BE RESPONSIBLE FOR
DAMAGE TO EQUIPMENT AS A RESULT OF IMPROPER
WIRING OR ELECTRICAL INSTALLATION. IT IS THE
CUSTOMERS RESPONSIBILITY TO ENSURE THAT THE
ELECTRICAL INSTALLATION IS CORRECT AND UP TO
APPLICABLE CODES.

When installing the dryer, ensure that the NEMA rating of the
control box is applicable to the installation.

Dryer is rated NEMA 4.


2.2

OPERATION SAFETY


DO NOT OPERATE THE DRYER ABOVE THE STATED
WORKING PRESSURE (SEE SPECIFICATION TABLE).
FAILURE, INJURY AND EQUIPMENT DAMAGE COULD
RESULT.

SECTION 3 SPECIFICATIONS

3.1

DIMENSIONS & WEIGHTS















Maximum Working Pressure: 150 PSIG

Maximum Ambient Temperature: 120° F

3.2

AIR FLOW CAPACITIES

FLOW MULTIPLIERS FOR VARIOUS PRESSURES

PRESSURE

80

90

100

110

120

MULTIPLIER

0.683

0.833

1.000

1.087

1.174

CAUTION:

EXCEPT as otherwise specified by the manufacturer, this
product is specifically designed for compressed air service
and use with any other gas or liquid is a misapplication. Use
with or injection of certain hazardous liquids or gases in the
system (i.e., alcohol or liquid petroleum gas) could be
harmful to the unit and result in a combustible condition or
cause hazardous external leakage. Manufacturer’s
warranties are void in the event of a misapplication and
manufacturer assumes NO RESPONSIBILITY for any
resulting loss. Before using equipment with fluids or gases
other than air, or for non-industrial applications, consult Van
Air Systems for written approval.

MODEL

H

W

D

P

A

B

PORTS

(npt)

MTG

HOLE

DIA.

WEIGHT

(lbs)

MHL3

13.6

7.4

5.2

9.3

5.8

2.8

3/8

8

MHL6

18.2

7.4

5.2

13.0

5.8

2.8

3/8

0.3

9

MHL9

17.3

7.4

5.2

12.1

5.8

2.8

3/8

0.3

10

MHL12

20.1

7.4

5.2

14.9

5.8

2.8

3/8

0.3

11

MHL16

33.0

9.5

6.5

20.7

7.0

23.6

1/2

0.4

29

MHL25

41.9

9.5

6.5

29.5

7.0

32.5

1/2

0.4

34

MHL35

39.3

10.0

7.0

26.5

9.0

30.1

1/2

0.4

59

NOTE: MHL16-MHL35 dryer shown with bracket top and bottom. MHL3-MHL12 has single 4-hole bracket.

Dimensions shown in inches.

0.3

MHL50

47.4

10.0

7.0

33.5

9.0

37.1

1/2

0.4

65

Advertising