SECTION 2

HANDLING

2.1 HANDLING INSTRUCTIONS

If the unit is to be lifted by an overhead device, attach the lifting
chains or cables to the vessel lifting lugs on the top head.

Models VME-5000 through VME-10000 are shipped without the
elements installed.
These elements are shipped separately in
wooden crates. Use extreme caution when unloading or moving the
elements with fork lifts. Always lift the crate from below the crate
supports to prevent the element from being pierced or torn.

2.2 STORAGE INSTRUCTIONS

If the unit is to be placed in storage before it is installed, the location
should be a clean, dry place. The ideal place to store the unit is
indoors. The location should be free from corrosive gasses and
extreme humidity. These conditions will cause damage to the unit.
The unit should be covered with a tarpaulin to keep the it clean.

If the unit is to be stored outdoors, it MUST BE covered completely
to prevent rain or snow from accumulating on the unit. The location

must be free of standing water and mud. If the location is outdoors,
a paved surface is recommended.

When storing the elements, they should be protected to prevent
them from being contaminated or saturated with water. Provisions
must be taken to prevent vermin from entering the elements and
using the element fibers for nesting material.

The large crated elements should be stored horizontally. Do not
stack them more than 4 crates high.

2.3 EQUIPMENT CHECK

Inspect the vessel and any elements for any damage that may have
occurred during shipment. Check the packing list to insure that all
items shipped with the unit are present.
IF EQUIPMENT HAS BEEN DAMAGED DURING SHIPMENT:

(1) NOTIFY CARRIER IMMEDIATELY.
(2) DO NOT OPERATE BEFORE CONSULTING FACTORY.

SECTION 3

SPECIFICATIONS AND DIMENSIONS

3.1 SPECIFICATIONS

VESSEL CONSTRUCTION

• Designed and manufactured to the ASME code plus current
addenda.
• Models VME-125 through VME-500 stamped "UM" symbol.
• Models VME-1250 through VME-10000 stamped "U" symbol.
• All models designed with a vessel corrosion allowance of
0.0625".
• Exterior primed white enamel finish.
• All flanged bolt holes oriented to straddle centerlines.

VESSEL WEIGHT (without elements)

VME-125 ........ 420 LBS
VME-250 ........ 440 LBS
VME-500 ........ 480 LBS
VME-850 ....... 525 LBS
VME-1250 ...... 710 LBS
VME-1500 ...... 820 LBS
VME-2000 ...... 1040 LBS
VME-2500 ...... 1170 LBS
VME-3000 ...... 1300 LBS
VME-7500 ...... 2500 LBS
VME-10000 .... 2720 LBS

NOTE: Models VME-125 through VME-3000 are shipped with the elements
factory installed.

ELEMENT WEIGHTS

EVME-125 ..... 20 LBS
EVME-250 ..... 20 LBS
EVME-500 ..... 35 LBS
EVME-850 ..... 50 LBS
EVME-1250 ... 60 LBS
EVME-1500 ... 70 LBS
EVME-2000 ... 90 LBS
EVME-2500 ... 120 LBS
EVME-3000 ... 150 LBS
EVME-5000 ... 235 LBS
EVME-7500 ... 400 LBS
EVME-10000 . 460 LBS

OPERATING PRESSURE RANGE (all models)

Minimum ........ 50 PSIG

Maximum ............... 150 PSIG

OPERATING TEMPERATURE (all models)

Maximum .......

300

O

F

RATED FLOW AT 100 PSIG, 100

O

F

VME-125 ........ 125 SCFM
VME-250 ........ 250 SCFM
VME-500 ........ 500 SCFM
VME-850 ....... 850 SCFM
VME-1250 ...... 1250 SCFM
VME-1500 ...... 1500 SCFM
VME-2000 ...... 2000 SCFM
VME-2500 ...... 2500 SCFM
VME-3000 ...... 3000 SCFM
VME-5000 ...... 5000 SCFM
VME-7500 ...... 7500 SCFM
VME-10000 .... 10000 SCFM

MULTIPLIERS FOR PRESSURES OTHER THAN 100 PSIG

Pressure

50 60 70 80

90 100 110 120 130 140 150

Multiplier

.56 .65 .74 .83 .91 1.00 1.09 1.17 1.26 1.35 1.44

MULTIPLIERS FOR TEMPERATURES OTHER THAN

100

O

F

Temp.

50

75

100 125 150 175 200 250

300

Multiplier

1.10 1.05 1.00 .96

.92

.88

.85

.79

.74

ELEMENT PRESSURE DROP

• Element pressure drop will be less than 1 PSID at initial start up

and throughout life.

• Element should be replaced when pressure drop reaches 3 PSID

ELEMENT EFFICIENCY

• 100% efficiency for particles over 3 MICRONS
• 99.5% efficiency for particles 3 MICRONS and less

MAXIMUM MIST CARRYOVER

• Mist carryover < 1 PPM, assuming an inlet loading of < 200 PPM

at 100

o

F inlet temperature.