FILTER HOUSING DIMENSIONS & WEIGHTS

DIMENSIONS FOR:

AHP-65

AHP-80

AHP-125

AHP-255

AHP-285

AHP-470

DIMENSIONS FOR:

AHP-25

AHP-40

*Insert appropriate filtration grade here; for example AHP-25-7.25-B.

**Flow is based on SCFM @ 725 PSIG @ 100°F.

FILTER MODEL

FLOW**

(SCFM)

IN/OUT

CONN.

(NPT)

A

B

C

D

HOUSING

WEIGHT

(LBS)

AHP-25-7.25-(*)

94

1/4"

2-1/2"

1/2"

6"

2"

0.5

AHP-40-7.25-(*)

147

3/8"

2-1/2"

1/2"

7-1/2"

2"

0.6

AHP-65-7.25-(*)

265

1/2"

4-1/2"

1-1/2"

12"

6"

5.7

AHP-80-7.25-(*)

324

3/4"

4-1/2"

1-1/2"

12"

6"

5.7

AHP-125-7.25-(*)

492

1"

4-1/2"

1-1/2"

15-1/2"

6"

7.3

AHP-255-7.25-(*)

1015

1-1/2"

5-3/4"

2"

21"

7"

16.5

AHP-285-7.25-(*)

1132

2"

5-3/4"

2"

21"

7"

16.5

AHP-470-7.25-(*)

1882

2"

5-3/4"

2"

25"

7"

22

FLOW CORRECTION FACTORS FOR OTHER PRESSURES

OPERATING

PRESSURE

100

PSIG

250

PSIG

300

PSIG

400

PSIG

500

PSIG

550

PSIG

600

PSIG

650

PSIG

700

PSIG

725

PSIG

Correction Factor

0.25

0.51

0.57

0.66

0.77

0.82

0.87

0.92

0.98

1.00

1. Before installing filter, check operating temperature and

pressure conditions to verify that they are within the specified

ranges.

(See Operating Conditions on page 1). Also verify

that system flow rate corresponds to the rated capacity of

the filter. Operating at flows above rated capacity will result

in increased pressure drop.

2. Locate Filter at the point of lowest operating temperature to

ensure that water and oil vapor do not condense downstream

of the filter. Filter should be installed close to the point of

use to minimize the risk of pipe scale, dirt, etc. recontaminat-

ing the compressed air. This is particularly important when

installing a new filter on an existing system that has not had

proper filtration.

3. Protect filter from reverse flow conditions. Do not install filter

downstream of quick opening valves.

4. Install filter vertically. Provide required minimum clearance

below filter to allow for replacement of element.

(See Element Removal Clearance on page 2).

5. Remove filter head from the bowl by turning bowl counter-

clockwise. Pull element from filter head. Set bowl and

element aside for use later.

INSTALLATION

6. Install inlet and outlet shutoff valves to facilitate replace-

ment of element. Bypass piping is recommended.

(See Fig-

ure 1A). MAKE SURE VALVES ARE CLOSED BEFORE

PROCEEDING.

7. Depressurize piping and connect filter head into piping. Avoid

reducers or bushings to match inlet size. The resulting restric-

tion will increase pressure drop. Make sure head is installed

with flow arrows pointing in proper direction. Use pipe thread

compound as required.

If multiple filters are being installed in series, use pipe nipples

to connect filters,

do not attempt to bolt filters together.

8. Install element by pushing into filter head.

IMPORTANT

INSTALL FILTER HEAD WITH ARROWS POINTING

IN THE PROPER DIRECTION TO ENSURE PROPER

OPERATION. (SEE FIGURE 1A).