SPECIFICATIONS AND DIMENSIONS

SECTION 3

3.1 SPECIFICATIONS

WEIGHT

AC-10-1 ............... 25 LBS

AC-20-1 .............. 27 LBS

AC-30-1 ............... 61 LBS

AC-40-1 .............. 67 LBS

DIMENSIONS .............. See Section 3.2

INLET/OUTLET CONNECTIONS

AC-10-1 ........ 1/2" NPT (F)

AC-20-1 ...... 1/2" NPT (F)

AC-30-1 ........ 1" NPT (F)

AC-40-1 ..... 1-1/2" NPT (F)

MAXIMUM WORKING PRESSURE

ALL MODELS ............ 250 PSIG

MAXIMUM WORKING TEMPERATURE

ALL MODELS ............ 350

O

F

ASSEMBLY, LEG INSTALLATION

SECTION 2

2.1 INSTALLING THE LEGS

This unit was shipped without the legs installed. The legs
should be installed before placing the aftercooler in the
piping system.

The legs can be mounted two ways:

1. Core mounted horizontally
2. Core mounted vertically

FIGURE 1 LEG INSTALLATION DETAIL

ELECTRICAL REQUIREMENTS

ALL MODELS ............ 115V-1PH-60Hz, w/ ODP motor

MATERIALS OF CONSTRUCTION

CABINET .................... Steel with baked enamel finish
FAN GUARD .............. Steel, zinc chromate plated
FAN ............................ Heavy gauge aluminum with steel hub
CORE ......................... Aluminum fins on copper tubes
MOTOR ...................... Open vented

MOTOR SPECIFICATIONS AND DATA

See Wiring Diagram, Figure 5 on page 6.

FAN DATA

(AMBIENT AIR FLOW)

AC-10-1 & AC-20-1 .... 615 SCFM
AC-30-1 & AC-40-1 .... 945 SCFM

MAXIMUM CAPACITY (SCFM)

Rated capacities are based on the following conditions: Inlet and approach temperature at inlet pressures 80 to 125 PSIG.

Approach Temperature: The number of degrees above the temperature of the cooling medium (in this case ambient air) to
which the aftercooler reduces the compressed air. A higher approach does not mean better performance.

INLET TEMP.

APPROACH
TEMP.

O

F

MODEL

AC-10-1

AC-20-1

AC-30-1

AC-40-1

15

35*

43*

72*

125*

10

35*

43*

72

125*

5

17

29

43

95

20

35*

43*

72*

125*

5

11

17

28

66

10

22

36

50

111

15

35

43*

70

125*

20

35*

43*

72*

125*

5

8

12

22

52

10

16

27

35

88

15

20

35

50

100

20

35

43*

70

125*

5

6

10

18

44

10

12

20

32

74

15

19

31

45

100

20

26

42*

57

125

5

5

8

15

38

10

10

16

28

64

15

15

26

39

86

20

21

35

50

108

150

O

F

200

O

F

350

O

F

250

O

F

300

O

F

MAXIMUM PRESSURE DROP LESS THAN 3 PSI.

*

Maximum ratings restricted by pressure drop: actual thermal capacities are higher.

Determine the desired position for your installation. Place the
aftercooler in that position (horizontal or vertical). Carefully lift
and support the unit approximately 1 to 2 feet from the floor.

Position the legs against the unit and fasten them in place
using the fasteners provided. Make sure the fasteners are
tightened in place.

Advertising