Subsequent starting of the generator – WEN 56551 5500 Watt User Manual

Page 20

Advertising
background image

17

To start your generator, perform the following steps:

1. No electrical devices should be connected to the generator during starting. Devices can

make it difficult for the engine to start.

2. Check that the generator is properly grounded (see “Ground the Generator”).
3. Check the oil and fuel levels.
4. Turn the fuel valve to the “ON” position (see figure 12).
5. Move the choke lever to the “CLOSE” position (see figure 13).
6. Set the engine switch to the “ON” position.
7. Pull on the recoil starter handle slowly until a slight resistance is felt (see figure 14). Then

pull quickly to start the engine. Return cord gently into the machine. Never allow the cord
to snap back.

8. If engine fails to start, repeat step 7. NOTE: After repeated failed attempts to start the

engine, please consult the troubleshooting guide before attempting again. If problems
persist please call (888) 315-3080 M-F 8-5 CST.

9. Once the engine has started, slowly return the choke lever all the way to the “OPEN”

position.

10. Allow the generator to run for several minutes before attempting to connect any electrical

devices. This allows the generator to stabilize its speed and temperature.

Figure 12- Fuel Valve in the “on” position

Figure 14- Pulling the start cord


Figure 13- Pull choke out for closed position.

Push in for open position.

SUBSEQUENT STARTING OF THE GENERATOR


If this is not the first time using the generator, user should take the following steps to prepare it for
operation.

IMPORTANT: At this point the user should be familiar with the procedures described in the
section titled “Using the Generator for the First Time.” If the user has not yet read this
section, go back and read it now.