MAINTENANCE / CARE

Proper routine maintenance of your generator will help prolong the life of your machine. Please
perform maintenance checks and operations according the schedule in figure 19.

If you have questions about any of the maintenance procedures listed in this manual, please

call (888) 315-3080 M-F 8-5CST.

CAUTION: Never perform maintenance operations while the generator is running.

Recommended Maintenance Schedule

each use

first month

then every

20 hrs

every 3

months or

50 hrs

every 6

months or

100 hrs

every year

or 300 hrs

Engine oil

check level

x

replace

x

x

Air cleaner

check

x

clean

x

fuel filter cup clean

x

spark plug

check/ clean

x

gas tank

check gas level

x

clean

x

Figure 19- Recommended maintenance schedule

Cleaning the Generator

Never clean the generator when it is running! Never clean with a bucket of water or a hose. Water
can get inside the working parts of the generator and cause a short circuit or corrosion.
Always try to use the generator in a cool, dry place. If the generator becomes dirty, clean the
exterior with a damp cloth, a soft brush, vacuum or pressurized air.

Checking the Oil

Check the oil level of the generator according to the Recommended Maintenance Schedule in
Figure 19. The generator is equipped with an automatic shutoff to protect it from running with low
oil pressure. The generator should be checked before each use for proper oil level. This is a
critical step for proper engine starting.

To check or add oil, follow these steps:

1. Make sure the generator is on a level surface. Clean around oil fill.
2. Remove the oil filler/dipstick cap and check oil level.
3. If oil level is below the second thread from the lip of the oil fill opening, slowly add oil

until the engine crankcase is filled.

4. Reinstall and tighten oil filler cap before starting the engine. .